Analysis of Free Chlorine in Aqueous Solution at Very Low Concentration with Lateral Flow Tests

Overview
Journal Sci Rep
Specialty Science
Date 2019 Nov 22
PMID 31748632
Citations 8
Authors
Affiliations
Soon will be listed here.
Abstract

Test strips are convenient tools for rapid, semi-quantitative analysis of a variety of parameters by dipping them for a few seconds in a sample solution followed by a simple colorimetric read-out. Their sensitivity is mainly determined by the reactivity of the test dyes on the reaction zone and is not sufficient for some applications. The detection limit of commercially available free chlorine test strips, for example, is at present not low enough to confirm the absence of this analyte as disinfectant in rinsing solutions after disinfection or to control required residual amounts of chlorine in drinking water. Therefore, we developed a user-friendly lateral flow test which is capable to detect very low amounts of free chlorine. The latter relies on a larger sample volume passing the reaction zone as compared to simple dip test strips. An amount of as low as 0.05 ppm chlorine can, however, only be detected if oxidation stable flow test substrates are used. The eventually developed flow test reaches a 10x higher sensitivity than a commercial dip test. The result is obtained within 4-5 min flow time, whereby no action is required by the user during this analysis time.

Citing Articles

Magnetic Particle Spectroscopy for Point-of-Care: A Review on Recent Advances.

Yari P, Rezaei B, Dey C, Chugh V, Veerla N, Wang J Sensors (Basel). 2023; 23(9).

PMID: 37177614 PMC: 10181768. DOI: 10.3390/s23094411.


Magnetic nanoparticles and magnetic particle spectroscopy-based bioassays: a 15 year recap.

Wu K, Liu J, Chugh V, Liang S, Saha R, Krishna V Nano Futures. 2022; 6(2).

PMID: 36199556 PMC: 9531898. DOI: 10.1088/2399-1984/ac5cd1.


Ten Years of Lateral Flow Immunoassay Technique Applications: Trends, Challenges and Future Perspectives.

Di Nardo F, Chiarello M, Cavalera S, Baggiani C, Anfossi L Sensors (Basel). 2021; 21(15).

PMID: 34372422 PMC: 8348896. DOI: 10.3390/s21155185.


Comparison of the disinfecting effect of sodium hypochlorite aqueous solution and surfactant on hospital kitchen hygiene using adenosine triphosphate swab testing.

Aoyama T, Kudo T PLoS One. 2021; 16(4):e0249796.

PMID: 33848316 PMC: 8043410. DOI: 10.1371/journal.pone.0249796.


Functional paper-based materials for diagnostics.

Hillscher L, Liebich V, Avrutina O, Biesalski M, Kolmar H ChemTexts. 2021; 7(2):14.

PMID: 33816066 PMC: 8010294. DOI: 10.1007/s40828-021-00139-w.


References
1.
Cho J, Paek S . Semiquantitative, bar code version of immunochromatographic assay system for human serum albumin as model analyte. Biotechnol Bioeng. 2001; 75(6):725-32. DOI: 10.1002/bit.10094. View

2.
Walji N, MacDonald B . Influence of Geometry and Surrounding Conditions on Fluid Flow in Paper-Based Devices. Micromachines (Basel). 2018; 7(5). PMC: 6190155. DOI: 10.3390/mi7050073. View

3.
Cate D, Noblitt S, Volckens J, Henry C . Multiplexed paper analytical device for quantification of metals using distance-based detection. Lab Chip. 2015; 15(13):2808-18. PMC: 4470859. DOI: 10.1039/c5lc00364d. View

4.
Saito T, Isogai A . TEMPO-mediated oxidation of native cellulose. The effect of oxidation conditions on chemical and crystal structures of the water-insoluble fractions. Biomacromolecules. 2004; 5(5):1983-9. DOI: 10.1021/bm0497769. View

5.
Laitinen M, Sojakka K, Vuento M . Thin-layer affinity chromatography in analysis of protein-ligand affinity. Anal Biochem. 1996; 243(2):279-82. DOI: 10.1006/abio.1996.0518. View