» Articles » PMID: 19154815

Development of Enzyme-based Bar Code-style Lateral-flow Assay for Hydrogen Peroxide Determination

Overview
Journal Anal Chim Acta
Publisher Elsevier
Specialty Chemistry
Date 2009 Jan 22
PMID 19154815
Citations 8
Authors
Affiliations
Soon will be listed here.
Abstract

A unique approach of developing a bar code version of lateral-flow enzymatic-based assay for the semi-quantification of hydrogen peroxide is described. The proposed assay system is mainly composed of a goat anti-mouse IgG-horseradish peroxidase conjugate (Gt anti-M IgG-HRP)-coated nitrocellulose (NC) membrane and a peroxidase substrate pad. Unlike the bar code immunochromatographic assay which depends on the stepwise capture of analyte, the principle of enzyme-based bar code lateral-flow assay is based on the different reaction time on successive lines due to the delay in 3,3',5,5'-tetramethylbenzidine (TMB) release. Hydrogen peroxide (H(2)O(2)) acts as a limiting factor which controls the rate of the enzymatic conversion of TMB to blue color complex. The system expresses the concentration of H(2)O(2) in micromole range as three distinct ladder bars in 9 min therefore without the need of any reading device. The major advantages of this assay are its easily readable result, and also its simplicity and low-cost in production offers a cheaper alternative for testing those expensive biosensors might not be available to the third world countries. By incorporating with H(2)O(2)-generating oxidoreductases, the assay can be further extended to detect a variety of analytes with clinical and environmental importance. Glucose was chosen to be the model analyte where the proposed system gave signal response at between 5 microM and 100 microM.

Citing Articles

Point-of-Care Diabetes Diagnostics: Towards a Self-Powered Sensor.

Vinagre I, Martins G, Alves J, Moreira F Micromachines (Basel). 2025; 16(2).

PMID: 40047575 PMC: 11857123. DOI: 10.3390/mi16020134.


Recent Advances in Quantum Dot-Based Lateral Flow Immunoassays for the Rapid, Point-of-Care Diagnosis of COVID-19.

Mousavi S, Kalashgrani M, Gholami A, Omidifar N, Binazadeh M, Chiang W Biosensors (Basel). 2023; 13(8).

PMID: 37622872 PMC: 10452855. DOI: 10.3390/bios13080786.


Paper-based analytical devices for virus detection: Recent strategies for current and future pandemics.

Ozer T, Henry C Trends Analyt Chem. 2021; 144:116424.

PMID: 34462612 PMC: 8387141. DOI: 10.1016/j.trac.2021.116424.


Integrating high-performing electrochemical transducers in lateral flow assay.

Perju A, Wongkaew N Anal Bioanal Chem. 2021; 413(22):5535-5549.

PMID: 33913001 PMC: 8410735. DOI: 10.1007/s00216-021-03301-y.


Counting-based microfluidic paper-based devices capable of analyzing submicroliter sample volumes.

Mahmud M, Blondeel E, MacDonald B Biomicrofluidics. 2020; 14(1):014107.

PMID: 31966347 PMC: 6954107. DOI: 10.1063/1.5131751.