Fracture Resistance of Teeth Restored with Endocrowns: An in Vitro Study

Overview
Specialty Dentistry
Date 2019 Nov 20
PMID 31743558
Citations 6
Authors
Affiliations
Soon will be listed here.
Abstract

Objective: The objective of this study is to evaluate the fracture resistance and failure mode of endodontically treated teeth restored with lithium disilicate endocrowns of different crown thicknesses.

Materials And Methods: A total of 30 endodontically treated permanent mandibular first molars were sectioned horizontally 2 mm above the highest point of the cemento-enamel junction. The specimens were divided into three groups, and each group was restored with lithium disilicate (IPS e-max press) endocrowns of different crown thicknesses (3, 4.5, and 6 mm, respectively). After cementation, specimens were stored in room temperature for 72 hours, followed by subjecting them to compressive strength testing until failure. The fracture loads and the failure mode were recorded. Statistically analysis was performed using one-way analysis of variance.

Results: A statistically significant difference was found in the fracture resistance between the three groups with the highest fracture resistance in the 3 mm group, followed by the 4.5 mm group, and the least in the 6 mm group (P < .05). Most of the failures were accompanied with tooth fracture (90% in 3 mm group, 100% in 4.5 mm group, and 80% in 6 mm group).

Conclusions: Increasing the crown thickness of the endocrowns reduced the fracture resistance of restored teeth. Minimum fracture loads for all teeth restored with endocrowns were significantly higher than the maximum occlusal forces reported in the literature.

Clinical Significance: Fracture resistance and mode of failure of lithium disilicate (IPS e-max press) endocrowns varies widely between crown thicknesses. Clinicians should be cautious with crown thickness for endocrown restorations.

Citing Articles

Influence of Ferrule Design and Occlusal Thickness on the Fracture Resistance and Failure Patterns of Zirconia Endocrowns.

Panda S, Patro T, Dhal A, Garhnayak L, Kumar U, Pattanaik N J Pharm Bioallied Sci. 2025; 16(Suppl 4):S3541-S3543.

PMID: 39926722 PMC: 11805103. DOI: 10.4103/jpbs.jpbs_1032_24.


Endocrown: A Minimally Invasive Alternative to Conventional Fixed Prosthesis.

Kirthiga M, Thomas G, Jose S, Shyam A, M A Cureus. 2024; 16(11):e74514.

PMID: 39726497 PMC: 11671110. DOI: 10.7759/cureus.74514.


Influence of Cementation Mode and Ferrule Design on the Fatigue Resistance of Monolithic Zirconia Endocrowns.

Stoilov M, Boehmer T, Stoilov L, Stark H, Marder M, Enkling N J Clin Med. 2024; 13(4).

PMID: 38398475 PMC: 10889707. DOI: 10.3390/jcm13041165.


Endocrowns - a literature review.

Ciobanu P, Manziuc M, Buduru S, Dudea D Med Pharm Rep. 2023; 96(4):358-367.

PMID: 37970193 PMC: 10642738. DOI: 10.15386/mpr-2581.


Fracture Strength of Endocrowns Fabricated From Three Different Computer-Aided Design/Computer-Aided Manufacturing Ceramic Materials: An In-Vitro Study.

Alshali S, Attar E Cureus. 2023; 15(7):e41531.

PMID: 37426406 PMC: 10328547. DOI: 10.7759/cureus.41531.