» Articles » PMID: 31653530

A Practical Guide to Assess the Reproducibility of Echocardiographic Measurements

Overview
Specialty Radiology
Date 2019 Oct 27
PMID 31653530
Citations 54
Authors
Affiliations
Soon will be listed here.
Abstract

Echocardiography plays an essential role in the diagnosis and assessment of cardiovascular disease. Measurements derived from echocardiography are also used to determine the severity of disease, its progression over time, and to aid in the choice of optimal therapy. It is therefore clinically important that echocardiographic measurements be reproducible, repeatable, and reliable. There are a variety of statistical tests available to assess these parameters, and in this article the authors summarize those available for use by echocardiographers to improve their clinical practice. Correlation coefficients, linear regression, Bland-Altman plots, and the coefficient of variation are explored, along with their limitations. The authors also provide an online tool for the easy calculation of these statistics in the clinical environment (www.birmingham.ac.uk/echo). Quantifying and enhancing the reproducibility of echocardiography has important potential to improve the value of echocardiography as the basis for good clinical decision-making.

Citing Articles

Predicting Cardiac Magnetic Resonance-Derived Ejection Fraction from Echocardiogram Via Deep Learning Approach in Tetralogy of Fallot.

Adhikari A, Wesley 3rd G, Nguyen M, Doan T, Rao M, Parthiban A Pediatr Cardiol. 2025; .

PMID: 40038120 DOI: 10.1007/s00246-025-03802-y.


Echocardiographic Evaluation of Indices of Severity of Pulmonary Stenosis in Dogs: Reproducibility and Effects of General Anesthesia.

Ross E, Visser L, Tantisuwat L, Mama K, Potter B, Scansen B J Vet Intern Med. 2025; 39(2):e70003.

PMID: 40008828 PMC: 11863216. DOI: 10.1111/jvim.70003.


Comprehensive transthoracic echocardiographic evaluation of doxorubicin-induced cardiotoxicity: a multimodal imaging approach in an animal model.

Haesen S, Steegen L, Deluyker D, Bito V Eur Heart J Imaging Methods Pract. 2025; 3(1):qyaf006.

PMID: 39974275 PMC: 11837189. DOI: 10.1093/ehjimp/qyaf006.


Deep Learning Applications in 12-lead Electrocardiogram and Echocardiogram.

Nakayama M, Yagi R, Goto S JMA J. 2025; 8(1):102-112.

PMID: 39926090 PMC: 11799486. DOI: 10.31662/jmaj.2024-0195.


Artificial intelligence-powered solutions for automated aortic diameter measurement in computed tomography: a narrative review.

Lo E, Chen S, Ng K, Wong R Ann Transl Med. 2025; 12(6):116.

PMID: 39817238 PMC: 11729799. DOI: 10.21037/atm-24-171.