» Articles » PMID: 31595372

Visual Aptamer-based Capillary Assay for Ethanolamine Using Magnetic Particles and Strand Displacement

Overview
Journal Mikrochim Acta
Specialties Biotechnology
Chemistry
Date 2019 Oct 10
PMID 31595372
Citations 1
Authors
Affiliations
Soon will be listed here.
Abstract

This work describes an aptamer-based capillary assay for ethanolamine (EA). It is making use of strand displacement format and magnetic particles. The capillary tubes are coated with three layers, viz. (a) first with short oligonucleotides complementary to the aptamer (EA-comp.); (b) then with magnetic particles (Dynabeads) coated with EA-binding aptamer (EA-aptamer), and (c) with short oligonucleotide-coated magnetic particles (EA-comp.). On exposure to a sample containing ethanolamine, the DNA-coated magnetic particles are released and subsequently collected and spatially separated using a permanent magnet. This results in the formation of a characteristic black/brown spots. The assay has a visual limit of detection of 5 nM and only requires 5 min of incubation. Quantification is possible through capture and analysis of digital (RGB) photos in the 5 to 75 nM EA concentration range. Furthermore, results from tap water and serum spiked with EA samples showed that the platform performs well in complex samples and can be applied to real sample analysis. The combined use of plastic capillaries, visual detection and passive flow make the method suited for implementation into a point-of-care device. Graphical abstract Schematic representation of the capillary assay steps.

Citing Articles

Emerging biotechnology applications in natural product and synthetic pharmaceutical analyses.

Chen S, Li Z, Zhang S, Zhou Y, Xiao X, Cui P Acta Pharm Sin B. 2022; 12(11):4075-4097.

PMID: 36386468 PMC: 9643291. DOI: 10.1016/j.apsb.2022.08.025.

References
1.
Mehlhorn A, Rahimi P, Joseph Y . Aptamer-Based Biosensors for Antibiotic Detection: A Review. Biosensors (Basel). 2018; 8(2). PMC: 6023021. DOI: 10.3390/bios8020054. View

2.
Brandhorst G, Oellerich M, Maine G, Taylor P, Veen G, Wallemacq P . Liquid chromatography-tandem mass spectrometry or automated immunoassays: what are the future trends in therapeutic drug monitoring?. Clin Chem. 2012; 58(5):821-5. DOI: 10.1373/clinchem.2011.167189. View

3.
Wang S, Zhang S, Liou L, Ren Q, Zhang Z, Caldwell G . Phosphatidylethanolamine deficiency disrupts α-synuclein homeostasis in yeast and worm models of Parkinson disease. Proc Natl Acad Sci U S A. 2014; 111(38):E3976-85. PMC: 4183298. DOI: 10.1073/pnas.1411694111. View

4.
Jonkheijm P, Weinrich D, Schroder H, Niemeyer C, Waldmann H . Chemical strategies for generating protein biochips. Angew Chem Int Ed Engl. 2008; 47(50):9618-47. DOI: 10.1002/anie.200801711. View

5.
Gamer A, Rossbacher R, Kaufmann W, van Ravenzwaay B . The inhalation toxicity of di- and triethanolamine upon repeated exposure. Food Chem Toxicol. 2008; 46(6):2173-83. DOI: 10.1016/j.fct.2008.02.020. View