» Articles » PMID: 31443348

Testing and Calibration of CDs As Radon Detectors at Highly Variable Radon Concentrations and Temperatures

Overview
Publisher MDPI
Date 2019 Aug 25
PMID 31443348
Citations 3
Authors
Affiliations
Soon will be listed here.
Abstract

The application of the compact disk (CD) method for radon measurements at mines, caves and other workplaces needs testing under highly variable exposure conditions. We present the results from a blind comparison of CDs exposed in the Laboratory of Natural Radiation (Saelices el Chico, Spain). During the exposure the temperature varied from 6.5 to 24.9 °C (average 12.6 °C) and the Rn activity concentrations varied from <10 Bq m to 147 kBq m. Good correspondence was observed between the integrated Rn activity concentration determined by the reference instruments in the laboratory (122,500 ± 6100 kBq h m) and that assessed by analysis of the CDs at a depth 80 µm beneath the front surface (118,000 ± 12,000 kBq h m) and at a depth of 120 µm (106,000 ± 12,000 kBq h m). The theoretical modeling of the CD response under variable temperature and radon concentration suggested that the small bias is probably due to the time variation of the calibration factor because of the time variations of the temperature.

Citing Articles

Radiation Detection-CD/DVD, Glass, and Emerging Materials for Radon Exposure Assessment.

Rathebe P, Kholopo M Sensors (Basel). 2024; 24(23).

PMID: 39686210 PMC: 11645005. DOI: 10.3390/s24237674.


Investigation of the Performance of Various Low-Cost Radon Monitors under Variable Environmental Conditions.

Rabago D, Fernandez E, Celaya S, Fuente I, Fernandez A, Quindos J Sensors (Basel). 2024; 24(6).

PMID: 38544099 PMC: 10975208. DOI: 10.3390/s24061836.


Intercomparison of Indoor Radon Measurements Under Field Conditions In the Framework of MetroRADON European Project.

Rabago D, Fuente I, Celaya S, Fernandez A, Fernandez E, Quindos J Int J Environ Res Public Health. 2020; 17(5).

PMID: 32182944 PMC: 7084476. DOI: 10.3390/ijerph17051780.

References
1.
Pressyanov D . Modeling a 222Rn measurement technique based on absorption in polycarbonates and track-etch counting. Health Phys. 2009; 97(6):604-12. DOI: 10.1097/01.HP.0000363841.55299.23. View

2.
Fuente M, Rabago D, Herrera S, Quindos L, Fuente I, Foley M . Performance of radon monitors in a purpose-built radon chamber. J Radiol Prot. 2018; 38(3):1111-1127. DOI: 10.1088/1361-6498/aad969. View

3.
Pressyanov D, Buysse J, Poffijn A, Meesen G, Van Deynse A . The compact disk as radon detector--a laboratory study of the method. Health Phys. 2003; 84(5):642-51. DOI: 10.1097/00004032-200305000-00011. View

4.
Pressyanov D, Mitev K, Georgiev S, Dimitrova I . Radon mapping by retrospective measurements - an approach based on CDs/DVDs. J Environ Radioact. 2010; 101(10):821-5. DOI: 10.1016/j.jenvrad.2010.02.009. View

5.
Dimitrov D, Pressyanov D . THE CD/DVD METHOD AS A TOOL FOR THE HEALTH PHYSICS SERVICE AND VENTILATION DIAGNOSTICS IN UNDERGROUND MINES. Radiat Prot Dosimetry. 2018; 181(1):30-33. DOI: 10.1093/rpd/ncy097. View