Reproducibility of Nasal Allergen Challenge Responses in Adults with Allergic Rhinitis

Overview
Journal Clin Pharmacol
Publisher Dove Medical Press
Specialty Pharmacology
Date 2019 Jun 14
PMID 31191044
Citations 3
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Allergic rhinitis is characterized by nasal inflammation in response to allergen exposure. Nasal allergen challenges are used in clinical trials evaluating drug effects. Reproducibility of nasal secretion cytokine responses and physiological measurements are needed to determine the optimum measurements and power calculations for future studies. We have investigated the reproducibility of nasal cytokine measurements, using ready-to-use polyvinyl acetate sponges to collect nasal secretions, and measurements of nasal physiological responses.

Methods: Twelve subjects with allergic rhinitis and no history of respiratory disease, and 12 subjects with asthma and allergic rhinitis underwent a nasal allergen challenge. This was repeated at 7-14 days later.

Results: There were increases in IL-5, CCL11, and CXCL8 responses post-challenge (all <0.05). There was better reproducibility at later time points when higher cytokine levels were detected for IL-5 ( =0.64 at 8 hours) and CXCL8 ( =0.91 at 8 hours). Acoustic rhinometry provided good to excellent reproducibility ( =0.66-0.89). Rhinomanometry had lower reproducibility with greater variation ( =0.10-0.70), with some subjects unable to perform the measurement. Multiplex immunoassays provided greater sensitivity for CCL11 measurements. There were no differences between allergic rhinitis patients with and without asthma.

Conclusion: Polyvinyl acetate sponges are a practical and reproducible way to sample nasal secretions. Acoustic rhinometry is a practical and reproducible method for assessing physiological responses. There were no differences in nasal response due to the presence of concurrent asthma.

Citing Articles

Altered expression of long noncoding RNAs regulating neutrophilic inflammation in peripheral blood was associated with symptom severity in patients with house dust mite-induced allergic rhinitis.

Zhao J, Pu X, Wang X, Zhang L Front Allergy. 2024; 5:1466480.

PMID: 39525400 PMC: 11543571. DOI: 10.3389/falgy.2024.1466480.


A new perspective on acoustic rhinometry in terms of standardisation, including the nasal allergen provocation test.

Krzych-Falta E, Kaczynska O, Samolinski B, Sybilski A Postepy Dermatol Alergol. 2022; 39(5):852-855.

PMID: 36457669 PMC: 9704467. DOI: 10.5114/ada.2021.109689.


Remote FEV1 Monitoring in Asthma Patients: A Pilot Study.

Huang C, Izmailova E, Jackson N, Ellis R, Bhatia G, Ruddy M Clin Transl Sci. 2020; 14(2):529-535.

PMID: 33048470 PMC: 7993258. DOI: 10.1111/cts.12901.

References
1.
Chakir J, Laviolette M, Turcotte H, Boutet M, Boulet L . Cytokine expression in the lower airways of nonasthmatic subjects with allergic rhinitis: influence of natural allergen exposure. J Allergy Clin Immunol. 2000; 106(5):904-10. DOI: 10.1067/mai.2000.110100. View

2.
Terada N, Hamano N, Kim W, Hirai K, Nakajima T, Yamada H . The kinetics of allergen-induced eotaxin level in nasal lavage fluid: its key role in eosinophil recruitment in nasal mucosa. Am J Respir Crit Care Med. 2001; 164(4):575-9. DOI: 10.1164/ajrccm.164.4.2009046. View

3.
Hilberg O . Objective measurement of nasal airway dimensions using acoustic rhinometry: methodological and clinical aspects. Allergy. 2002; 57 Suppl 70:5-39. DOI: 10.1046/j.0908-665x.2001.all.doc.x. View

4.
Riechelmann H, Bachert C, Goldschmidt O, Hauswald B, Klimek L, Schlenter W . [Application of the nasal provocation test on diseases of the upper airways. Position paper of the German Society for Allergology and Clinical Immunology (ENT Section) in cooperation with the Working Team for Clinical Immunology]. Laryngorhinootologie. 2003; 82(3):183-8. DOI: 10.1055/s-2003-38411. View

5.
Beeh K, Beier J, Kornmann O, Meier C, Taeumer T, Buhl R . A single nasal allergen challenge increases induced sputum inflammatory markers in non-asthmatic subjects with seasonal allergic rhinitis: correlation with plasma interleukin-5. Clin Exp Allergy. 2003; 33(4):475-82. DOI: 10.1046/j.1365-2222.2003.01632.x. View