The world's population is aging: the expansion of the older adult population with multiple physical and health issues is now a huge socio-economic concern worldwide. Among these issues, the loss of mobility among older adults due to musculoskeletal disorders is especially serious as it has severe social, mental and physical consequences. Human body joint monitoring and early diagnosis of these disorders will be a strong and effective solution to this problem. A smart joint monitoring system can identify and record important musculoskeletal-related parameters. Such devices can be utilized for continuous monitoring of joint movements during the normal daily activities of older adults and the healing process of joints (hips, knees or ankles) during the post-surgery period. A viable monitoring system can be developed by combining miniaturized, durable, low-cost and compact sensors with the advanced communication technologies and data processing techniques. In this study, we have presented and compared different joint monitoring methods and sensing technologies recently reported. A discussion on sensors' data processing, interpretation, and analysis techniques is also presented. Finally, current research focus, as well as future prospects and development challenges in joint monitoring systems are discussed.

Citing Articles

Effect of baseline values on inpatient rehabilitation outcomes after total knee arthroplasty: a retrospective observational study.

Missmann M, Fischer M J Rehabil Med. 2025; 57:jrm40443.

PMID: 39849999 PMC: 11780670. DOI: 10.2340/jrm.v57.40443.


Multiscale Wettability of Microtextured Irregular Surfaces.

Peta K Materials (Basel). 2024; 17(23).

PMID: 39685152 PMC: 11642355. DOI: 10.3390/ma17235716.


Reliability of motion phase identification for long-track speed skating using inertial measurement units.

Iizuka T, Tomita Y PeerJ. 2024; 12:e18102.

PMID: 39351374 PMC: 11441384. DOI: 10.7717/peerj.18102.


Accuracy Validation of a Sensor-Based Inertial Measurement Unit and Motion Capture System for Assessment of Lower Limb Muscle Strength in Older Adults-A Novel and Convenient Measurement Approach.

Zhu Y, Li H, Wu X, Chen N Sensors (Basel). 2024; 24(18).

PMID: 39338786 PMC: 11435846. DOI: 10.3390/s24186040.


Just-in-Time Adaptive Interventions for Behavior Change in Physiological Health Outcomes and the Use Case for Knee Osteoarthritis: Systematic Review.

Fiedler J, Bergmann M, Sell S, Woll A, Stetter B J Med Internet Res. 2024; 26:e54119.

PMID: 39331951 PMC: 11470223. DOI: 10.2196/54119.


References
1.
Moromizato K, Kimura R, Fukase H, Yamaguchi K, Ishida H . Whole-body patterns of the range of joint motion in young adults: masculine type and feminine type. J Physiol Anthropol. 2016; 35(1):23. PMC: 5045662. DOI: 10.1186/s40101-016-0112-8. View

2.
Dhaher Y, Kahn L . The effect of vastus medialis forces on patello-femoral contact: a model-based study. J Biomech Eng. 2003; 124(6):758-67. DOI: 10.1115/1.1516196. View

3.
Murray C, Vos T, Lozano R, Naghavi M, Flaxman A, Michaud C . Disability-adjusted life years (DALYs) for 291 diseases and injuries in 21 regions, 1990-2010: a systematic analysis for the Global Burden of Disease Study 2010. Lancet. 2012; 380(9859):2197-223. DOI: 10.1016/S0140-6736(12)61689-4. View

4.
Majumder S, Chen L, Marinov O, Chen C, Mondal T, Deen M . Noncontact Wearable Wireless ECG Systems for Long-Term Monitoring. IEEE Rev Biomed Eng. 2018; 11:306-321. DOI: 10.1109/RBME.2018.2840336. View

5.
Saul K, Hu X, Goehler C, Vidt M, Daly M, Velisar A . Benchmarking of dynamic simulation predictions in two software platforms using an upper limb musculoskeletal model. Comput Methods Biomech Biomed Engin. 2014; 18(13):1445-58. PMC: 4282829. DOI: 10.1080/10255842.2014.916698. View