Mapping Sources of Noise in an Intensive Care Unit

Overview
Journal Anaesthesia
Specialty Anesthesiology
Date 2019 May 9
PMID 31066046
Citations 32
Authors
Affiliations
Soon will be listed here.
Abstract

Excessive noise in hospitals adversely affects patients' sleep and recovery, causes stress and fatigue in staff and hampers communication. The World Health Organization suggests sound levels should be limited to 35 decibels. This is probably unachievable in intensive care units, but some reduction from current levels should be possible. A preliminary step would be to identify principal sources of noise. As part of a larger project investigating techniques to reduce environmental noise, we installed a microphone array system in one with four beds in an adult general intensive care unit. This continuously measured locations and sound pressure levels of noise sources. This report summarises results recorded over one year. Data were collected between 7 April 2017 and 16 April 2018 inclusive. Data for a whole day were available for 248 days. The sound location system revealed that the majority of loud sounds originated from extremely limited areas, very close to patients' ears. This proximity maximises the adverse effects of high environmental noise levels for patients. Some of this was likely to be appropriate communication between the patient, their caring staff and visitors. However, a significant proportion of loud sounds may originate from equipment alarms which are sited at the bedside. A redesign of the intensive care unit environment to move alarm sounds away from the bed-side might significantly reduce the environmental noise burden to patients.

Citing Articles

Sustainable reduction in sound levels on intensive care units through noise management - an implementation study.

Witek S, Schmoor C, Montigel F, Grotejohann B, Ziegler S BMC Health Serv Res. 2025; 25(1):9.

PMID: 39748252 PMC: 11697813. DOI: 10.1186/s12913-024-12059-9.


The effect of an improved ICU physical environment on outcomes and post-ICU recovery-a protocol.

Tronstad O, Zangerl B, Patterson S, Flaws D, Yerkovich S, Szollosi I Trials. 2024; 25(1):376.

PMID: 38863018 PMC: 11167845. DOI: 10.1186/s13063-024-08222-6.


Application Effect of Comprehensive Noise Reduction Technology in Outpatients with Vitiligo: A Retrospective Study.

Liu Y, Wang J, Huo J, Zhang S, Han L, Lei Y Noise Health. 2024; 26(120):37-43.

PMID: 38570309 PMC: 11141697. DOI: 10.4103/nah.nah_60_23.


Mitigating Intensive Care Unit Noise: Design-Led Modeling Solutions, Calculated Acoustic Outcomes, and Cost Implications.

Jonescu E, Farrel B, Ramanayaka C, White C, Costanzo G, Delaney L HERD. 2024; 17(3):220-238.

PMID: 38512990 PMC: 11457460. DOI: 10.1177/19375867241237501.


Noise exposure among staff in intensive care units and the effects of unit-based noise management: a monocentric prospective longitudinal study.

Armbruster C, Walzer S, Witek S, Ziegler S, Farin-Glattacker E BMC Nurs. 2023; 22(1):460.

PMID: 38057790 PMC: 10699060. DOI: 10.1186/s12912-023-01611-3.


References
1.
Darbyshire J, Young J . An investigation of sound levels on intensive care units with reference to the WHO guidelines. Crit Care. 2013; 17(5):R187. PMC: 4056361. DOI: 10.1186/cc12870. View

2.
White R, Smith J, Shepley M . Recommended standards for newborn ICU design, eighth edition. J Perinatol. 2013; 33 Suppl 1:S2-16. DOI: 10.1038/jp.2013.10. View

3.
Darbyshire J, Hinton L, Young J, Greig P . Using the experience-based co-design method to design a teaching package. Med Educ. 2018; 52(11):1198. PMC: 6690073. DOI: 10.1111/medu.13720. View

4.
Muller-Trapet M, Cheer J, Maria Fazi F, Darbyshire J, Young J . Acoustic source localization with microphone arrays for remote noise monitoring in an Intensive Care Unit. Appl Acoust. 2018; 139:93-100. PMC: 6039849. DOI: 10.1016/j.apacoust.2018.04.019. View

5.
Basner M, Babisch W, Davis A, Brink M, Clark C, Janssen S . Auditory and non-auditory effects of noise on health. Lancet. 2013; 383(9925):1325-1332. PMC: 3988259. DOI: 10.1016/S0140-6736(13)61613-X. View