Background: There are some controversial reports related to the pro-arrhythmic or anti-arrhythmic potential of cardiac resynchronization therapy (CRT) and little is known about the relationship between ventricular arrhythmia (VA) and left ventricular (LV)-lead threshold.

Hypothesis: Upgrade CRT is anti-arrhythmic effect of VA with implantable cardioverter-defibrillator (ICD) patients and has a relationship with the incident of VA and LV-lead threshold.

Methods: Among 384 patients with the implantation of CRT-defibrillator (CRT-D), 102 patients underwent an upgrade from ICD to CRT-D. We divided patients into three groups; anti-arrhythmic effect after upgrade (n = 22), pro-arrhythmic effect (n = 14), and unchanging-VA events (n = 66). The VA event was determined by device reports. We described the electrocardiography parameters, LV-lead characteristics, and clinical outcomes.

Results: Before upgrade, the numbers of VA were 305 episodes and the numbers of ICD therapy were 157 episodes. While after upgrade, the numbers of VA were 193 episodes and the number of ICD therapy were 74 episodes. Ventricular tachycardia cycle length (VT-CL) after upgrade was significantly slower as compared to those with before upgrade. Pro-arrhythmic group was significantly higher with delta LV-lead threshold (after 1 month-baseline) as compared to those with anti-arrhythmic group (0.74 vs -0.21 V). Furthermore, pro-arrhythmic group was significantly bigger with delta VT-CL (after 3 months-before 3 months) as compared to those with anti-arrhythmic group (P = .03).

Conclusions: We described upgrade-CRT was associated with reduction of VA, ICD therapies and VT-CL. While 14 patients had a pro-arrhythmic effect and LV lead threshold might be associated with VA-incidents.

Citing Articles

New Diseases Related to Cardiac Implantable Electronic Devices (CIEDs): An Overview.

Crea P, Cocuzza F, Bonanno S, Ferrara N, Teresi L, La Maestra D J Clin Med. 2025; 14(4).

PMID: 40004852 PMC: 11856071. DOI: 10.3390/jcm14041322.


Proarrhythmic effect of bipolar epicardial left ventricular stimulation in CRT resolved maintaining biventricular pacing with unipolar-cathodical configuration: A peculiar case report.

Magnano M, Devecchi C, Oriente D, Occhetta E, Rametta F J Arrhythm. 2023; 39(2):192-197.

PMID: 37021028 PMC: 10068944. DOI: 10.1002/joa3.12818.


Upgrading right ventricular pacemakers to biventricular pacing or conduction system pacing: a systematic review and meta-analysis.

Kaza N, Htun V, Miyazawa A, Simader F, Porter B, Howard J Europace. 2022; 25(3):1077-1086.

PMID: 36352513 PMC: 10062368. DOI: 10.1093/europace/euac188.


Use of Stereotactic Radioablation Therapy as a Bailout Therapy for Refractory Ventricular Tachycardia in a Patient with a No-entry Left Ventricle.

Aras D, Ozturk H, Ozdemir E, Kervan U, Kara M, Cay S J Innov Card Rhythm Manag. 2021; 12(9):4671-4675.

PMID: 34595050 PMC: 8476093. DOI: 10.19102/icrm.2021.120902.


Association left ventricular lead and ventricular arrhythmias after upgrade to cardiac resynchronization therapy in patients with implantable cardioverter defibrillators.

Kawamura M, Arai S, Yoshikawa K, Gokan T, Ogawa K, Ochi A Clin Cardiol. 2019; 42(7):670-677.

PMID: 31056759 PMC: 6605005. DOI: 10.1002/clc.23192.

References
1.
Gasparini M, Lunati M, Landolina M, Santini M, Padeletti L, Perego G . Electrical storm in patients with biventricular implantable cardioverter defibrillator: incidence, predictors, and prognostic implications. Am Heart J. 2008; 156(5):847-54. DOI: 10.1016/j.ahj.2008.06.035. View

2.
Arya A, Haghjoo M, Dehghani M, Alasti M, Alizadeh H, Kazemi B . Effect of cardiac resynchronization therapy on the incidence of ventricular arrhythmias in patients with an implantable cardioverter-defibrillator. Heart Rhythm. 2005; 2(10):1094-8. DOI: 10.1016/j.hrthm.2005.07.007. View

3.
Basu Ray I, Fendelander L, Singh J . Cardiac resynchronization therapy and its potential proarrhythmic effect. Clin Cardiol. 2007; 30(10):498-502. PMC: 6653034. DOI: 10.1002/clc.17. View

4.
Kawamura M, Arai S, Yoshikawa K, Gokan T, Ogawa K, Ochi A . Association left ventricular lead and ventricular arrhythmias after upgrade to cardiac resynchronization therapy in patients with implantable cardioverter defibrillators. Clin Cardiol. 2019; 42(7):670-677. PMC: 6605005. DOI: 10.1002/clc.23192. View

5.
Di Biase L, Gasparini M, Lunati M, Santini M, Landolina M, Boriani G . Antiarrhythmic effect of reverse ventricular remodeling induced by cardiac resynchronization therapy: the InSync ICD (Implantable Cardioverter-Defibrillator) Italian Registry. J Am Coll Cardiol. 2008; 52(18):1442-9. DOI: 10.1016/j.jacc.2008.07.043. View