» Articles » PMID: 30993431

Dose to the Interventional Radiologist in CTF-guided Procedures

Overview
Date 2019 Apr 18
PMID 30993431
Citations 1
Authors
Affiliations
Soon will be listed here.
Abstract

The aim of this work was to assess the occupational dose received by an interventional radiologist (IR) during computed tomography fluoroscopy (CTF)-guided procedures; to identify the most exposed areas of the body including the hands and fingers; to suggest recommendations for individual monitoring; and to improve radiation safety of the practice. A total of 53 CTF-guided procedures were studied. Twelve whole-body dosimeters were worn by the IR in each procedure for the assessment of the personal dose equivalent, H(10), on the chest, waist, and back, both over and under the lead apron, as well as the personal dose equivalent, H(0.07), on both arms, knees, and feet. Special gloves with casings to fit extremity dosimeters were prepared to assess H(0.07) to the fingers. The measured chest dose values were higher than those on the waist and back; the dominant hand or the left side was the most exposed. In general, the ring, middle, and index fingers of the dominant hand were the most exposed (maximum in the 36-39 mSv range), while wrist dose was negligible compared to finger doses. Based on the results obtained the following recommendations are suggested: protective devices (lead aprons, thyroid shield, and goggles) should be worn; H(10) should be assessed at the chest level both above and below the lead apron; finger doses can be measured on the basis of each middle finger; the arm closer to the beam should be monitored; and finally, a wrist dosimeter will not provide useful information.

Citing Articles

Impact of interventionalist's experience and gender on radiation dose and procedural time in CT-guided interventions-a retrospective analysis of 4380 cases over 10 years.

Theilig D, Mayerhofer A, Petschelt D, Elkilany A, Hamm B, Gebauer B Eur Radiol. 2020; 31(2):569-579.

PMID: 32851446 PMC: 8263432. DOI: 10.1007/s00330-020-07185-x.

References
1.
Irie T, Kajitani M, Itai Y . CT fluoroscopy-guided intervention: marked reduction of scattered radiation dose to the physician's hand by use of a lead plate and an improved I-I device. J Vasc Interv Radiol. 2001; 12(12):1417-21. DOI: 10.1016/s1051-0443(07)61701-1. View

2.
Noppen M, de Mey J, Meysman M, Opdebeeck B, Vincken W, Osteaux M . Percutaneous needle biopsy of localized pulmonary, mediastinal, and pleural diseased tissue with an automatic disposable guillotine soft-tissue needle. Preliminary results. Chest. 1995; 107(6):1615-20. DOI: 10.1378/chest.107.6.1615. View

3.
Katada K, Kato R, ANNO H, Ogura Y, Koga S, Ida Y . Guidance with real-time CT fluoroscopy: early clinical experience. Radiology. 1996; 200(3):851-6. DOI: 10.1148/radiology.200.3.8756943. View

4.
Kato R, Katada K, ANNO H, Suzuki S, Ida Y, Koga S . Radiation dosimetry at CT fluoroscopy: physician's hand dose and development of needle holders. Radiology. 1996; 201(2):576-8. DOI: 10.1148/radiology.201.2.8888264. View

5.
Silverman S, Tuncali K, Adams D, Nawfel R, Zou K, Judy P . CT fluoroscopy-guided abdominal interventions: techniques, results, and radiation exposure. Radiology. 1999; 212(3):673-81. DOI: 10.1148/radiology.212.3.r99se36673. View