» Articles » PMID: 30992480

Clinical Efficacy of Professional Continuous Glucose Monitoring in Improving Glycemic Control Among Children with Type 1 Diabetes Mellitus: An Open-label Randomized Control Trial

Overview
Journal Sci Rep
Specialty Science
Date 2019 Apr 18
PMID 30992480
Citations 12
Authors
Affiliations
Soon will be listed here.
Abstract

Frequent self-monitoring of blood glucose (SMBG) is the only accurate method available for insulin dose titration in patients with T1DM. Professional continuous glucose monitoring (p-CGM) is blinded recording of glucose trends over 5-7 days and helps physicians to guide insulin titration to patient. This study was planned to assess efficacy of insulin dose adjustments, based on p-CGM plus SMBG in improving glycemic control compared to SMBG alone. We did an open-label, parallel design, randomized control trial among children (2-10 years) having T1DM for at least 6 months. Subjects in the intervention group were placed on p-CGM (iPRO 2™ Professional CGM, Medtronic, USA) for 3-5 days along with regular SMBG. Data from p-CGM was analyzed by physician and used to guide insulin titration along with SMBG over following 3 months. Control group had only SMBG records for titrating insulin doses. Primary outcome was change in HbA1c 3 months after intervention. A total of 68 eligible children were randomized, 34 each to either arms. Thirty children in intervention group and 33 in control group completed the study and were analyzed. It was found that there was more decreased unit change in HbA1c, percentage of low sugar records and total insulin requirement per day, after 3 months follow-up, in intervention group. However, difference was not significant except for total insulin Units/kg/day (p = 0.014). In sub-group analysis of children with baseline HbA1c >7.5%, there was a significant mean fall of HbA1c by 1.27% (p = 0.045). There were no major adverse events associated with p-CGM. We conclude that addition of p-CGM along with SMBG may help in adjusting insulin dose more effectively especially in children with higher baseline HbA1c.

Citing Articles

Telemedicine in Improving Glycemic Control Among Children and Adolescents With Type 1 Diabetes Mellitus: Systematic Review and Meta-Analysis.

Zhang K, Huang Q, Wang Q, Li C, Zheng Q, Li Z J Med Internet Res. 2024; 26:e51538.

PMID: 38981114 PMC: 11267117. DOI: 10.2196/51538.


Utility and precision evidence of technology in the treatment of type 1 diabetes: a systematic review.

Jacobsen L, Sherr J, Considine E, Chen A, Peeling S, Hulsmans M Commun Med (Lond). 2023; 3(1):132.

PMID: 37794113 PMC: 10550996. DOI: 10.1038/s43856-023-00358-x.


The Utility and Safety of a Continuous Glucose Monitoring System (CGMS) in Asphyxiated Neonates during Therapeutic Hypothermia.

Giordano L, Perri A, Tiberi E, Sbordone A, Patti M, DAndrea V Diagnostics (Basel). 2023; 13(18).

PMID: 37761385 PMC: 10530216. DOI: 10.3390/diagnostics13183018.


Evidence from clinical trials on high-risk medical devices in children: a scoping review.

Guerlich K, Patro-Golab B, Dworakowski P, Fraser A, Kammermeier M, Melvin T Pediatr Res. 2023; 95(3):615-624.

PMID: 37758865 PMC: 10899114. DOI: 10.1038/s41390-023-02819-4.


Use of Continuous Glucose Monitoring System in Children with Type 1 Diabetes Mellitus in a Resource Limited Setting.

Kiran S, Nagarajappa V, Sathyanarayana S, Hegde A, Raghupathy P Indian J Endocrinol Metab. 2023; 27(3):208-212.

PMID: 37583401 PMC: 10424105. DOI: 10.4103/ijem.ijem_376_22.


References
1.
Nathan D, Genuth S, Lachin J, Cleary P, Crofford O, Davis M . The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus. N Engl J Med. 1993; 329(14):977-86. DOI: 10.1056/NEJM199309303291401. View

2.
Ludvigsson J, Hanas R . Continuous subcutaneous glucose monitoring improved metabolic control in pediatric patients with type 1 diabetes: a controlled crossover study. Pediatrics. 2003; 111(5 Pt 1):933-8. DOI: 10.1542/peds.111.5.933. View

3.
Sternberg F, Meyerhoff C, Mennel F, Bischof F, Pfeiffer E . Subcutaneous glucose concentration in humans. Real estimation and continuous monitoring. Diabetes Care. 1995; 18(9):1266-9. DOI: 10.2337/diacare.18.9.1266. View

4.
Rebrin K, Steil G, van Antwerp W, Mastrototaro J . Subcutaneous glucose predicts plasma glucose independent of insulin: implications for continuous monitoring. Am J Physiol. 1999; 277(3):E561-71. DOI: 10.1152/ajpendo.1999.277.3.E561. View

5.
Boland E, Monsod T, Delucia M, Brandt C, Fernando S, Tamborlane W . Limitations of conventional methods of self-monitoring of blood glucose: lessons learned from 3 days of continuous glucose sensing in pediatric patients with type 1 diabetes. Diabetes Care. 2001; 24(11):1858-62. DOI: 10.2337/diacare.24.11.1858. View