Abstract

Data are lacking regarding the impact of visible pigment on rectal swab diagnostic accuracy. We describe the test characteristics of rectal swabs with and without pigment in children with gastroenteritis. Between December 2014 and September 2017, children (age, <18 years) with ≥3 episodes of vomiting and/or diarrhea in a 24-h period and symptoms for <7 days were enrolled through two pediatric emergency departments and from a province-wide nursing telephone advice line in Alberta, Canada. Specimens were analyzed by employing nucleic acid amplification panels. The primary outcomes were the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for the rectal swabs, with stool specimen results being used as the reference standard. An enteropathogen was detected in 76.0% (1,399/1,841) of the paired specimens. A total of 54.4% (1,001/1841) of the swabs had visible pigment. The respective enteropathogen detection characteristics of swabs with and without visible pigment were as follows: 92.2% (95% confidence interval [CI], 90.0%, 94.0%) versus 83.7% (95% CI, 80.5%, 86.4%) for sensitivity, 94.3% (95% CI, 90.5%, 96.6%) versus 91.2% (95% CI, 86.3%, 94.5%) for specificity, 97.9% (95% CI, 96.4%, 98.8%) versus 96.5% (95% CI, 94.5%, 97.8%) for PPV, and 80.9% (95% CI, 76.0%, 85.1%) versus 65.8% (95% CI, 60.0%, 71.1%) for NPV. Processing of swabs without visible pigment would increase the rate of identification of positive swabs from 50.0% (682/1,365) to 88.3% (1,205/1,365). There is a modest decrease in the reliability of a negative test on swabs without evidence of pigment, but the overall yield is significantly greater when they are not excluded from testing. Hence, rectal swabs without visible feces should not be routinely rejected from testing.

Citing Articles

Comparison of a Rapid Multiplex Gastrointestinal Panel with Standard Laboratory Testing in the Management of Children with Hematochezia in a Pediatric Emergency Department: Randomized Controlled Trial.

Xie J, Kim K, Berenger B, Chui L, Vanderkooi O, Grisaru S Microbiol Spectr. 2023; 11(3):e0026823.

PMID: 37039648 PMC: 10269456. DOI: 10.1128/spectrum.00268-23.


Differences in Illness Severity among Circulating Norovirus Genotypes in a Large Pediatric Cohort with Acute Gastroenteritis.

Bhavanam S, Freedman S, Lee B, Zhuo R, Qiu Y, Chui L Microorganisms. 2020; 8(12).

PMID: 33256234 PMC: 7760397. DOI: 10.3390/microorganisms8121873.


Rectal Swabs as an Alternative Sample Collection Method to Bulk Stool for the Real-Time PCR Detection of .

Maasch J, Arzika A, Cook C, Lebas E, Pilotte N, Grant J Am J Trop Med Hyg. 2020; 103(3):1276-1282.

PMID: 32524959 PMC: 7470573. DOI: 10.4269/ajtmh.19-0909.


Evaluation of the FecalSwab for Stool Specimen Storage and Molecular Detection of Enteropathogens on the BD Max System.

Richard-Greenblatt M, Rutherford C, Luinstra K, Cardenas A, Pang X, Jayaratne P J Clin Microbiol. 2020; 58(9).

PMID: 32461284 PMC: 7448620. DOI: 10.1128/JCM.00178-20.


A prospective comparative study of children with gastroenteritis: emergency department compared with symptomatic care at home.

Vanderkooi O, Xie J, Lee B, Pang X, Chui L, Payne D Eur J Clin Microbiol Infect Dis. 2019; 38(12):2371-2379.

PMID: 31502119 DOI: 10.1007/s10096-019-03688-8.

References
1.
Guerrant R, Van Gilder T, Steiner T, Thielman N, Slutsker L, Tauxe R . Practice guidelines for the management of infectious diarrhea. Clin Infect Dis. 2001; 32(3):331-51. DOI: 10.1086/318514. View

2.
Thomas M . Disadvantages of the rectal swab in diagnosis of diarrhoea. Br Med J. 1954; 2(4884):394-6. PMC: 2079024. DOI: 10.1136/bmj.2.4884.394. View

3.
Denno D, Shaikh N, Stapp J, Qin X, Hutter C, Hoffman V . Diarrhea etiology in a pediatric emergency department: a case control study. Clin Infect Dis. 2012; 55(7):897-904. PMC: 3657524. DOI: 10.1093/cid/cis553. View

4.
Claas E, Burnham C, Mazzulli T, Templeton K, Topin F . Performance of the xTAG® gastrointestinal pathogen panel, a multiplex molecular assay for simultaneous detection of bacterial, viral, and parasitic causes of infectious gastroenteritis. J Microbiol Biotechnol. 2013; 23(7):1041-5. DOI: 10.4014/jmb.1212.12042. View

5.
Kabayiza J, Andersson M, Welinder-Olsson C, Bergstrom T, Muhirwa G, Lindh M . Comparison of rectal swabs and faeces for real-time PCR detection of enteric agents in Rwandan children with gastroenteritis. BMC Infect Dis. 2013; 13:447. PMC: 3850680. DOI: 10.1186/1471-2334-13-447. View