» Articles » PMID: 30888484

Objective and Subjective Comparison of Virtual Monoenergetic Vs. Polychromatic Images in Patients with Pancreatic Ductal Adenocarcinoma

Overview
Journal Eur Radiol
Specialty Radiology
Date 2019 Mar 20
PMID 30888484
Citations 27
Authors
Affiliations
Soon will be listed here.
Abstract

Objectives: The aim of this study was to assess the objective and subjective image characteristics of monoenergetic images (MEI[+]), using a noise-optimized algorithm at different kiloelectron volts (keV) compared to polyenergetic images (PEI), in patients with pancreatic ductal adenocarcinoma (PDAC).

Methods: This retrospective, institutional review board-approved study included 45 patients (18 male, 27 female; mean age 66 years; range, 42-96 years) with PDAC who had undergone a dual-energy CT (DECT) of the abdomen for staging. One standard polyenergetic image (PEI) and five MEI(+) images in 10-keV intervals, ranging from 40 to 80 keV, were reconstructed. Line-density profile analysis, as well as the contrast-to-noise ratio (CNR) of the tumor, the signal-to-noise ratio (SNR) of the regular pancreas parenchyma and the tumor, and the CNR of the three main peripancreatic vessels, was calculated. For subjective quality assessment, two readers independently assessed the images using a 5-point Likert scale. Reader reliability was evaluated using an intraclass correlation coefficient.

Results: Line-density profile analysis revealed the largest gradient in attenuation between PDAC and regular tissue in MEI(+) at 40 keV. Low-keV MEI(+)reconstructions at 40 and 50 keV increased CNR and SNR compared to PEI (40 keV: CNR 46.8 vs. 7.5; SNR 32.5 vs. 15.7; SNR 13.5 vs. 8.6; p < 0.001). MEI(+) at 40 keV and 50 keV were consistently preferred by the observers (p < 0.05), showing a high intra-observer 0.937 (0.92-0.95) and inter-observer 0.911 (0.89-0.93) agreement.

Conclusion: MEI(+) reconstructions at 40 keV and 50 keV provide better objective and subjective image quality compared to conventional PEI of DECT in patients with PDAC.

Key Points: • Low-keV MEI(+) reconstructions at 40 and 50 keV increase tumor-to-pancreas contrast compared to PEI. • Low-keV MEI(+) reconstructions improve objective and subjective image quality parameters compared to PEI. • Dual-energy post-processing might be a valuable tool in the diagnostic workup of patients with PDAC.

Citing Articles

Reduced-dose CT scan of colorectal cancer.

Li S, Yang X, Cao Y, Yuan L, Lu T, Wang Y Abdom Radiol (NY). 2025; .

PMID: 39794537 DOI: 10.1007/s00261-024-04660-7.


Optimal virtual monoenergy for the detection of pancreatic adenocarcinoma during the pancreatic parenchymal phase on photon counting CT.

Ruff A, Li X, Goldberg J, Ehrhart M, Ginocchio L, Smereka P Abdom Radiol (NY). 2025; .

PMID: 39775026 DOI: 10.1007/s00261-024-04696-9.


An update on pancreatic cancer imaging, staging, and use of the PACT-UK radiology template pre- and post-neoadjuvant treatment.

Corallo C, Al-Adhami A, Jamieson N, Valle J, Radhakrishna G, Moir J Br J Radiol. 2024; 98(1165):13-26.

PMID: 39460945 PMC: 11652714. DOI: 10.1093/bjr/tqae217.


Diagnostic Value of Contrast-Enhanced Dual-Energy Computed Tomography in the Pancreatic Parenchymal and Delayed Phases for Pancreatic Cancer.

Kurita Y, Utsunomiya D, Kubota K, Koyama S, Hasegawa S, Hosono K Tomography. 2024; 10(10):1591-1604.

PMID: 39453034 PMC: 11510840. DOI: 10.3390/tomography10100117.


Photon-counting detector computed tomography: iodine density versus virtual monoenergetic imaging of pancreatic ductal adenocarcinoma.

Alagic Z, Duran C, Suzuki C, Halldorsson K, Svensson-Marcial A, Saeter R Abdom Radiol (NY). 2024; .

PMID: 39400586 DOI: 10.1007/s00261-024-04605-0.


References
1.
Jeon S, Lee J, Joo I, Lee D, Ahn S, Woo H . Magnetic resonance with diffusion-weighted imaging improves assessment of focal liver lesions in patients with potentially resectable pancreatic cancer on CT. Eur Radiol. 2018; 28(8):3484-3493. DOI: 10.1007/s00330-017-5258-1. View

2.
Rassouli N, Chalian H, Rajiah P, Dhanantwari A, Landeras L . Assessment of 70-keV virtual monoenergetic spectral images in abdominal CT imaging: A comparison study to conventional polychromatic 120-kVp images. Abdom Radiol (NY). 2017; 42(10):2579-2586. DOI: 10.1007/s00261-017-1151-2. View

3.
Muenzel D, Lo G, Yu H, Parakh A, Patino M, Kambadakone A . Material density iodine images in dual-energy CT: Detection and characterization of hypervascular liver lesions compared to magnetic resonance imaging. Eur J Radiol. 2017; 95:300-306. DOI: 10.1016/j.ejrad.2017.08.035. View

4.
Zhao L, Li F, Zhang Z, Zhang Z, Jiang Y, Wang X . Assessment of an advanced virtual monoenergetic reconstruction technique in cerebral and cervical angiography with third-generation dual-source CT: Feasibility of using low-concentration contrast medium. Eur Radiol. 2018; 28(10):4379-4388. DOI: 10.1007/s00330-018-5407-1. View

5.
Grant K, Flohr T, Krauss B, Sedlmair M, Thomas C, Schmidt B . Assessment of an advanced image-based technique to calculate virtual monoenergetic computed tomographic images from a dual-energy examination to improve contrast-to-noise ratio in examinations using iodinated contrast media. Invest Radiol. 2014; 49(9):586-92. DOI: 10.1097/RLI.0000000000000060. View