» Articles » PMID: 30835397

Noise Exposure and Self-reported Hearing Impairment Among Gas-fired Electric Plant Workers in Tanzania

Overview
Journal Ann Glob Health
Publisher Ubiquity Press
Date 2019 Mar 6
PMID 30835397
Citations 10
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Gas-fired electric plants are equipped with heavy machines, which produce hazards including noise pollution. Exposure to high level of noise of above 85dB(A) is known to bring about Noise-Induced Hearing Loss (NIHL). This study aimed to assess noise exposure level and reported prevalence of noise-induced hearing loss among workers in gas-fired electric plants.

Material And Methods: This cross-sectional study was conducted in three gas-fired electric plants in Dar es Salaam (Plant A, Plant B and Plant C) from July to August 2017. A noise logging dosimeter was used to measure personal noise exposure level. A questionnaire was used to collect information on managerial factors, individual factors, socio-demographic factors and history of the participants. A short screening validated questionnaire was used to obtain noise exposure score. Frequency distribution, Chi-square test and Regression analyses were done using SPSS version 20. Results: One hundred and six participants were involved in the study. Noise exposure level among gas-fired electric plant workers was above 85dB(A), n = 37. The equivalent sound level (LAeq) measured over 8 hours was (98.6 ± 9.7) dB(A). The mean noise peak level was (139.5 ± 9.4) dB(A). Plant C had higher mean noise exposure level (TWA) of (96.9 ± 5.1) dB(A) compared to plant B 96.4 ± 3.7dB(A) and plant A 78.7 ± 11.9dB(A). Participants in both operation and maintenance had higher equivalent sound level (LAeq) measured over eight hours of 101.980 ± 3.6dB(A) compared to maintenance alone 98.5 ± 12.4dB (A) or operation 97.7 ± 8.8dB (A). Proportion of participants with reported hearing loss was 57(53.8%) where 44(41.5%) participants reported difficulty hearing people during conversations. Hearing protective devices (HPDs) were reported to be used by a majority, 101(95.3%).

Conclusion: Workers in gas-fired plants are exposed to high noise levels that could damage their hearing. Hearing conservation programs should be established and maintained in this work environment.

Citing Articles

The Global Prevalence of Noise Induced Hearing Impairment Among Industrial Workers: A Systematic Review and Meta-Analysis.

Salari N, Hosseinian-Far A, Zarei H, Rasoulpoor S, Ghasemi H, Elyasi H Indian J Otolaryngol Head Neck Surg. 2024; 76(6):5035-5049.

PMID: 39559031 PMC: 11569344. DOI: 10.1007/s12070-024-05032-9.


Work-Life Conflict, Burnout, and Associated Factors Among Hydroelectric Power Plant Employees: A Cross-Sectional Study in Turkey.

Medeni I, Medeni V, Demirbas O, Ilhan M Cureus. 2024; 16(7):e64425.

PMID: 39130877 PMC: 11317102. DOI: 10.7759/cureus.64425.


An Exploratory Study on Self-Reported Auditory Symptoms and Hearing Loss among Workers in a Small-Scale LPG Plant.

Chand A, Manoharan A, Kumari L Indian J Occup Environ Med. 2024; 28(2):94-99.

PMID: 39114100 PMC: 11302531. DOI: 10.4103/ijoem.ijoem_44_23.


Noise Exposure in Palestinian Workers Without a Diagnosis of Hearing Impairment: Relations to Speech-Perception-in-Noise Difficulties, Tinnitus, and Hyperacusis.

Shehabi A, Prendergast G, Guest H, Plack C J Speech Lang Hear Res. 2023; 66(3):1085-1109.

PMID: 36802819 PMC: 10205103. DOI: 10.1044/2022_JSLHR-22-00461.


Occupational Noise-Induced Pre-Hypertension and Determinant Factors Among Metal Manufacturing Workers in Gondar City Administration, Northwest Ethiopia.

Melese M, Adera A, Ambelu A, Gela Y, Diress M Vasc Health Risk Manag. 2023; 19:21-30.

PMID: 36687313 PMC: 9851053. DOI: 10.2147/VHRM.S392876.


References
1.
Hessel P . Hearing loss among construction workers in Edmonton, Alberta, Canada. J Occup Environ Med. 2000; 42(1):57-63. DOI: 10.1097/00043764-200001000-00014. View

2.
. ACOEM evidence-based statement: noise-induced hearing loss. J Occup Environ Med. 2003; 45(6):579-81. DOI: 10.1097/00043764-200306000-00001. View

3.
Mbuligwe S . Levels and influencing factors of noise pollution from small-scale industries (SSIs) in a developing country. Environ Manage. 2004; 33(6):830-9. DOI: 10.1007/s00267-003-0060-z. View

4.
Hong O . Hearing loss among operating engineers in American construction industry. Int Arch Occup Environ Health. 2005; 78(7):565-74. DOI: 10.1007/s00420-005-0623-9. View

5.
Nelson D, Nelson R, Concha-Barrientos M, Fingerhut M . The global burden of occupational noise-induced hearing loss. Am J Ind Med. 2005; 48(6):446-58. DOI: 10.1002/ajim.20223. View