» Articles » PMID: 30774091

Successful Treatment of Unexpected Complication During Aortic Stent-grafting: Retrieval of Broken Stent-graft Tip by Coaxial Technique

Overview
Date 2019 Feb 19
PMID 30774091
Authors
Affiliations
Soon will be listed here.
Abstract

Thoracic aortic endovascular repair (TEVAR) is increasingly preferred as a treatment of choice in thoracic aortic diseases. Intravascular foreign body is one of the TEVAR-related complications similar to the other endovascular operations. Here, to the our best knowledge for the first time in the English literature, this report presents an extremely rare complication of a broken and stuck tip part of aortic stent-graft in the intravascular space and successful removal by using the coaxial technique. Thoracic aortic endovascular repair (TEVAR) has been increasingly preferred as the treatment of choice in thoracic aortic diseases (1). Endovascular treatment has been gaining popularity compared with open surgery due to its less invasive approach and rapid application, and allows the patient to easily return to daily life (2). However, TEVAR is associated with several specific complications including paraplegia, stroke, vascular injuries and local complications. These complications depend on vascular or nonvascular comorbidities, vascular anatomy, equipment, and experience of the provider (3-6). Intravascular foreign body could be among TEVAR-related complications similar to other endovascular operations (7). Several types of equipment, including guidewire, vascular sheath, or suboptimally uncoiled stents may get stuck in the intravascular space, causing complications (8). Herein, to the best of our knowledge, we present the first report in the English literature of broken and stuck tip part of an aortic stent-graft in the intravascular space and its successful removal using the coaxial technique.

References
1.
Seong C, Kim Y, Chung J, Kim S, Han J, Kim H . Tubular foreign body or stent: safe retrieval or repositioning using the coaxial snare technique. Korean J Radiol. 2002; 3(1):30-7. PMC: 2713984. DOI: 10.3348/kjr.2002.3.1.30. View

2.
Mitchell R, Ishimaru S, Ehrlich M, Iwase T, Lauterjung L, Shimono T . First International Summit on Thoracic Aortic Endografting: roundtable on thoracic aortic dissection as an indication for endografting. J Endovasc Ther. 2002; 9 Suppl 2:II98-105. View

3.
Tateishi M, Tomizawa Y . Intravascular foreign bodies: danger of unretrieved fragmented medical devices. J Artif Organs. 2009; 12(2):80-9. DOI: 10.1007/s10047-009-0447-6. View

4.
Fanelli F, Gazzetti M, Boatta E, Ruggiero M, Lucatelli P, Speziale F . Acute left arm ischemia associated with floating thrombus in the proximal descending aorta: combined endovascular and surgical therapy. Cardiovasc Intervent Radiol. 2010; 34(1):193-7. DOI: 10.1007/s00270-010-9804-3. View

5.
Follis F, Filippone G, Stabile A, Montalbano G, Floriano M, Finazzo M . Endovascular graft deployment in the false lumen of type B dissection. Interact Cardiovasc Thorac Surg. 2010; 10(4):597-9. DOI: 10.1510/icvts.2009.223040. View