Comparative Evaluation of the Effect of Electrolyzed Oxidizing Water on Surface Detail Reproduction, Dimensional Stability and Surface Texture of Poly Vinyl Siloxane Impressions

Overview
Specialty Dentistry
Date 2019 Feb 13
PMID 30745752
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

Aim: The aim of this study was to comparatively evaluate the effect of chemical disinfectants on the surface detail reproduction, dimensional stability and surface texture of polyvinyl siloxane (PVS) impressions.

Materials And Methods: The impressions were then divided into five groups (fifteen samples per group) and subjected to a ten minutes immersion with 2% glutaraldehyde (Group I), 1% sodium hypochlorite (Group II), freshly prepared electrolyzed oxidizing water (EOW) with different pH values - acidic (Group III), alkali (Group IV) and neutral (Group V). The samples were examined pre and post-immersion under visual observation for surface detail reproduction, travelling microscope for measurement of dimensional stability and surface profilometer (3D) for evaluation of surface texture. A standardized master die was fabricated and seventy-five PVS test samples were made. The samples were subjected to immersion disinfection and studied for surface detail reproduction, dimensional stability and surface texture. test, paired test and ANOVA were used to analyze dimensional stability statistically both within and between the test groups.

Results: The surface detail reproduction was satisfactory with both pre and post-immersion test samples. A statistically significant dimensional change was observed post-immersion in Groups II, III and V test samples and a statistically insignificant dimensional change was observed in Groups I and IV test samples. There was a negligible change in surface texture post-immersion in Groups I, III, IV and V test samples with a slight increase in surface roughness post-immersion in Group II samples.

Conclusion: In this study, all the test disinfectants produced satisfactory surface detail reproduction on Polyvinyl siloxane impressions. 2% glutaraldehyde and electrolyzed oxidizing water (alkali) have resulted in statistically insignificant dimensional change, while 1% sodium hypochlorite, electrolyzed oxidizing water (acidic) and electrolyzed oxidizing water (neutral) have resulted in statistically significant dimensional changes. All the test disinfectants except 1% sodium hypochlorite showed a reduction in surface roughness (Ra) values.

Citing Articles

Effects of Various Disinfection Methods on the Material Properties of Silicone Dental Impressions of Different Types and Viscosities.

Wezgowiec J, Paradowska-Stolarz A, Malysa A, Orzeszek S, Seweryn P, Wieckiewicz M Int J Mol Sci. 2022; 23(18).

PMID: 36142778 PMC: 9505442. DOI: 10.3390/ijms231810859.


Assessment of Effect of Different Sterilization Agents on Dimensional Accuracy of Different Impression Materials in Implant Prosthesis - An Study.

Kavita K, Reddy K, Reddy K, Kumar S, Pandey G, Singh R J Pharm Bioallied Sci. 2022; 13(Suppl 2):S1620-S1623.

PMID: 35018041 PMC: 8686873. DOI: 10.4103/jpbs.jpbs_315_21.


3D cone-beam C.T. imaging used to determine the effect of disinfection protocols on the dimensional stability of full arch impressions.

Hsu K, Balhaddad A, Garcia I, Collares F, Dhar V, DePaola L Saudi Dent J. 2021; 33(7):453-461.

PMID: 34803286 PMC: 8589573. DOI: 10.1016/j.sdentj.2020.12.001.


Effect of heat sterilization and chemical method of sterilization on the polyvinyl siloxane impression material. A comparative study.

Asopa S, Padiyar U, Verma S, Suri P, Somayaji N, Radhakrishnan I J Family Med Prim Care. 2020; 9(3):1348-1353.

PMID: 32509614 PMC: 7266257. DOI: 10.4103/jfmpc.jfmpc_1122_19.


Effect of chemical, microwave irradiation, steam autoclave, ultraviolet light radiation, ozone and electrolyzed oxidizing water disinfection on properties of impression materials: A systematic review and meta-analysis study.

AlZain S Saudi Dent J. 2020; 32(4):161-170.

PMID: 32405219 PMC: 7211894. DOI: 10.1016/j.sdentj.2019.12.003.

References
1.
Adabo G, Zanarotti E, Fonseca R, Cruz C . Effect of disinfectant agents on dimensional stability of elastomeric impression materials. J Prosthet Dent. 1999; 81(5):621-4. DOI: 10.1016/s0022-3913(99)70219-2. View

2.
Marais J, Brozel V . Electro-chemically activated water in dental unit water lines. Br Dent J. 1999; 187(3):154-8. DOI: 10.1038/sj.bdj.4800228. View

3.
Taylor R, Wright P, Maryan C . Disinfection procedures: their effect on the dimensional accuracy and surface quality of irreversible hydrocolloid impression materials and gypsum casts. Dent Mater. 2002; 18(2):103-10. DOI: 10.1016/s0109-5641(01)00027-6. View

4.
Muller-Bolla M, Lupi-Pegurier L, Velly A, Bolla M . A survey of disinfection of irreversible hydrocolloid and silicone impressions in European Union dental schools: epidemiologic study. Int J Prosthodont. 2004; 17(2):165-71. View

5.