» Articles » PMID: 30666447

Initial Exploration of Coronary Stent Image Subtraction Using Dual-layer Spectral CT

Overview
Journal Eur Radiol
Specialty Radiology
Date 2019 Jan 23
PMID 30666447
Citations 3
Authors
Affiliations
Soon will be listed here.
Abstract

Objectives: This study aimed to investigate the feasibility of coronary stent image subtraction using spectral tools derived from dual-layer spectral computed tomography (CT).

Methods: Forty-three patients (65 stents) who underwent coronary CT angiography using dual-layer spectral CT were included. Conventional, 50-keV (kilo electron-volt), 100-keV, and virtual non-contrast (VNC) images were reconstructed from the same cardiac phase. Stents were subtracted on VNC images from conventional (conv), 100-keV (100-keV), and 50-keV (50-keV) images. The in-stent lumen diameters were measured on subtraction, conventional, and 100-keV images. Subjective evaluation of reader confidence and subtractive quality was evaluated. Friedman tests were performed to compare in-stent lumen diameters and subjective evaluation among different images. Correlation between stent diameter and subjective evaluation was expressed as Spearman's rank correlation coefficient (r). The diagnostic accuracy was assessed according to invasive coronary angiography (ICA) performed in 11 patients (20 stents).

Results: In-stent lumen diameters were significantly larger on subtraction images than those on conventional and 100-keV images (p < 0.05). Higher reader confidence was found on 100-keV, conv, 100-keV, and 50-keV images compared with conventional images (p < 0.05). Subtractive quality of 100-keV images was better than that of conv images (p = 0.037). A moderate-to-strong correlation between stent diameter and subjective evaluation was found (r = 0.527~0.790, p < 0.05). Higher specificity, positive predictive value, and negative predictive value of subtraction images were shown by ICA results.

Conclusions: Subtraction images derived from dual-layer spectral CT enhanced in-stent lumen visibility and could potentially improve diagnostic performance for evaluating coronary stents.

Key Points: • Dual-layer spectral CT enabled good subtractive quality of coronary stents without misregistration artifacts. • Subtraction images could improve in-stent lumen visibility. • Reader confidence and diagnostic performance were enhanced with subtraction images.

Citing Articles

Monoenergetic reconstructions and iodine density maps for visualization of coronary artery stents using 8-cm dual-layer detector spectral computed tomography: an phantom study.

Chen L, Pan N, Hu B, Li Y, Dong S, Zhou Y Quant Imaging Med Surg. 2024; 14(10):7671-7683.

PMID: 39429615 PMC: 11485354. DOI: 10.21037/qims-24-786.


[Assessment of Coronary Stenosis Using Coronary CT Angiography in Patients with High Calcium Scores: Current Limitations and Future Perspectives].

Kang D J Korean Soc Radiol. 2024; 85(2):270-296.

PMID: 38617859 PMC: 11009141. DOI: 10.3348/jksr.2023.0134.


Iodine-based extracellular volume for evaluating myocardial status in patients undergoing percutaneous coronary intervention for acute myocardial infarction by using dual-layer spectral detector computed tomography: a comparison study with magnetic....

Liang J, Li H, Xie J, Yu H, Chen W, Yin K Quant Imaging Med Surg. 2022; 12(9):4502-4511.

PMID: 36060604 PMC: 9403598. DOI: 10.21037/qims-21-1103.

References
1.
de Vet H, Terwee C, Knol D, Bouter L . When to use agreement versus reliability measures. J Clin Epidemiol. 2006; 59(10):1033-9. DOI: 10.1016/j.jclinepi.2005.10.015. View

2.
Maintz D, Burg M, Seifarth H, Bunck A, Ozgun M, Fischbach R . Update on multidetector coronary CT angiography of coronary stents: in vitro evaluation of 29 different stent types with dual-source CT. Eur Radiol. 2008; 19(1):42-9. DOI: 10.1007/s00330-008-1132-5. View

3.
Halpern E, Halpern D, Yanof J, Amin-Spector S, Fischman D, Aviram G . Is coronary stent assessment improved with spectral analysis of dual energy CT?. Acad Radiol. 2009; 16(10):1241-50. DOI: 10.1016/j.acra.2009.04.011. View

4.
Kottner J, Audige L, Brorson S, Donner A, Gajewski B, Hrobjartsson A . Guidelines for Reporting Reliability and Agreement Studies (GRRAS) were proposed. J Clin Epidemiol. 2010; 64(1):96-106. DOI: 10.1016/j.jclinepi.2010.03.002. View

5.
Andreini D, Pontone G, Bartorelli A, Mushtaq S, Trabattoni D, Bertella E . High diagnostic accuracy of prospective ECG-gating 64-slice computed tomography coronary angiography for the detection of in-stent restenosis: in-stent restenosis assessment by low-dose MDCT. Eur Radiol. 2011; 21(7):1430-8. DOI: 10.1007/s00330-011-2085-7. View