» Articles » PMID: 30651804

Long-term Graft Patency After Coronary Artery Bypass Grafting: Effects of Surgical Technique

Overview
Journal Exp Ther Med
Specialty Pathology
Date 2019 Jan 18
PMID 30651804
Citations 4
Authors
Affiliations
Soon will be listed here.
Abstract

The aim of the current study was to identify surgical factors associated with long-term patency of grafts used in coronary artery bypass grafting (CABG). The present study analyzed data from 127 patients who underwent CABG at our institute between 2000 and 2006 and presented for ambulatory examination and coronary computed tomography angiography evaluation of graft patency in 2016 (139.78±36.64 months post-CABG). The 127 patients received 340 grafts (2.68 grafts/patient) and 399 distal anastomoses (3.14 anastomoses/patient), 220 (55.14%) with arterial grafts and 179 (44.86%) with saphenous vein grafts. Graft patency varied according to coronary territory, proximal anastomosis type ( graft, composite graft, graft anastomosed to the ascending aorta), Y anastomosis angle (47.21° for patent arterial grafts vs. 56° for occluded), and distal anastomosis angle (in sequential anastomoses irrespective to graft type, 48.60° for patent side-to-side anastomosis vs. 53.97° for occluded, 65.12° for patent end-to-side anastomosis vs. 90.80° for occluded; in single end-to-side anastomosis of arterial grafts, 39.46° for patent and 44.94° for occluded). A single end-to-side anastomosis angle 60° or greater was associated with a 5.149 occlusion odds ratio (OR) (P<0.001) for arterial grafts. Venous grafts were not sensitive to single end-to-side anastomosis angle. In conclusion, a small anastomosis angle for proximal Y and distal anastomoses is associated with a higher long-term patency of the free graft. Radial artery grafts registered higher patency rates when anastomosed to the ascending aorta compared with composite grafting with the left internal thoracic artery, whereas right internal thoracic artery (RITA) anastomosed to the right coronary territory is associated with a lower patency rate compared with free RITA used to revascularise the anterolateral or circumflex territory in composite grafting.

Citing Articles

Improvement of the outcome of the saphenous vein graft when connected to the internal thoracic artery.

Katsavrias K, Prapas S, Calafiore A, Taggart D, Angouras D, Iliopoulos D Front Cardiovasc Med. 2024; 11:1478166.

PMID: 39494236 PMC: 11527685. DOI: 10.3389/fcvm.2024.1478166.


Sex-specific disparities in patients undergoing isolated CABG.

Dassanayake M, Norton E, Ward A, Wenger N Am Heart J Plus. 2024; 35:100334.

PMID: 38511179 PMC: 10945894. DOI: 10.1016/j.ahjo.2023.100334.


Anatomy of the septal perforating arteries of the heart.

Kim S Anat Cell Biol. 2019; 52(3):236-241.

PMID: 31598351 PMC: 6773898. DOI: 10.5115/acb.18.175.


A mathematical model to evaluate hemodynamic effects of the graft anastomosis in coronary surgery.

Ruvolo G, Pisano C, Bertoldo F, Russo M, Verzicco R, Nardi P Kardiochir Torakochirurgia Pol. 2019; 16(2):106-108.

PMID: 31410101 PMC: 6690154. DOI: 10.5114/kitp.2019.86366.

References
1.
Dion R, Glineur D, Derouck D, Verhelst R, Noirhomme P, El Khoury G . Long-term clinical and angiographic follow-up of sequential internal thoracic artery grafting. Eur J Cardiothorac Surg. 2000; 17(4):407-14. DOI: 10.1016/s1010-7940(00)00370-5. View

2.
Calafiore A, Contini M, Vitolla G, DI Mauro M, Mazzei V, Teodori G . Bilateral internal thoracic artery grafting: long-term clinical and angiographic results of in situ versus Y grafts. J Thorac Cardiovasc Surg. 2000; 120(5):990-6. DOI: 10.1067/mtc.2000.110249. View

3.
Song M, Sato M, Ueda Y . Three-dimensional simulation of coronary artery bypass grafting with the use of computational fluid dynamics. Surg Today. 2000; 30(11):993-8. DOI: 10.1007/s005950070019. View

4.
Taggart D, DAmico R, Altman D . Effect of arterial revascularisation on survival: a systematic review of studies comparing bilateral and single internal mammary arteries. Lancet. 2001; 358(9285):870-5. DOI: 10.1016/S0140-6736(01)06069-X. View

5.
Bonert M, Myers J, Fremes S, Williams J, Ethier C . A numerical study of blood flow in coronary artery bypass graft side-to-side anastomoses. Ann Biomed Eng. 2002; 30(5):599-611. DOI: 10.1114/1.1481052. View