» Articles » PMID: 30618785

Modeling Left Atrial Flow, Energy, Blood Heating Distribution in Response to Catheter Ablation Therapy

Overview
Journal Front Physiol
Date 2019 Jan 9
PMID 30618785
Citations 8
Authors
Affiliations
Soon will be listed here.
Abstract

Atrial fibrillation (AF) is a widespread cardiac arrhythmia that commonly affects the left atrium (LA), causing it to quiver instead of contracting effectively. This behavior is triggered by abnormal electrical impulses at a specific site in the atrial wall. Catheter ablation (CA) treatment consists of isolating this driver site by burning the surrounding tissue to restore sinus rhythm (SR). However, evidence suggests that CA can concur to the formation of blood clots by promoting coagulation near the heat source and in regions with low flow velocity and blood stagnation. A patient-specific modeling workflow was created and applied to simulate thermal-fluid dynamics in two patients pre- and post-CA. Each model was personalized based on pre- and post-CA imaging datasets. The wall motion and anatomy were derived from SSFP Cine MRI data, while the trans-valvular flow was based on Doppler ultrasound data. The temperature distribution in the blood was modeled using a modified Pennes bioheat equation implemented in a finite-element based Navier-Stokes solver. Blood particles were also classified based on their residence time in the LA using a particle-tracking algorithm. SR simulations showed multiple short-lived vortices with an average blood velocity of 0.2-0.22 m/s. In contrast, AF patients presented a slower vortex and stagnant flow in the LA appendage, with the average blood velocity reduced to 0.08-0.14 m/s. Restoration of SR also increased the blood kinetic energy and the viscous dissipation due to the presence of multiple vortices. Particle tracking showed a dramatic decrease in the percentage of blood remaining in the LA for longer than one cycle after CA (65.9 vs. 43.3% in patient A and 62.2 vs. 54.8% in patient B). Maximum temperatures of 76° and 58°C were observed when CA was performed near the appendage and in a pulmonary vein, respectively. This computational study presents novel models to elucidate relations between catheter temperature, patient-specific atrial anatomy and blood velocity, and predict how they change from SR to AF. The models can quantify blood flow in critical regions, including residence times and temperature distribution for different catheter positions, providing a basis for quantifying stroke risks.

Citing Articles

The role of the pulmonary veins on left atrial flow patterns and thrombus formation.

Mill J, Harrison J, Saiz-Vivo M, Albors C, Morales X, Olivares A Sci Rep. 2024; 14(1):5860.

PMID: 38467726 PMC: 11639444. DOI: 10.1038/s41598-024-56658-2.


Comprehensive left atrial flow component analysis reveals abnormal flow patterns in paroxysmal atrial fibrillation.

Back S, Lantz J, Skoda I, Henriksson L, Persson A, Karlsson L Am J Physiol Heart Circ Physiol. 2023; 326(3):H511-H521.

PMID: 38133621 PMC: 11221802. DOI: 10.1152/ajpheart.00614.2023.


Personalized biomechanical insights in atrial fibrillation: opportunities & challenges.

Telle A, Bargellini C, Chahine Y, Del Alamo J, Akoum N, Boyle P Expert Rev Cardiovasc Ther. 2023; 21(11):817-837.

PMID: 37878350 PMC: 10841537. DOI: 10.1080/14779072.2023.2273896.


Imaging and biophysical modelling of thrombogenic mechanisms in atrial fibrillation and stroke.

Qureshi A, Lip G, Nordsletten D, Williams S, Aslanidi O, de Vecchi A Front Cardiovasc Med. 2023; 9:1074562.

PMID: 36733827 PMC: 9887999. DOI: 10.3389/fcvm.2022.1074562.


Regional left atrial conduction velocity in the anterior wall is associated with clinical recurrence of atrial fibrillation after catheter ablation: efficacy in combination with the ipsilateral low voltage area.

Ohguchi S, Inden Y, Yanagisawa S, Fujita R, Yasuda K, Katagiri K BMC Cardiovasc Disord. 2022; 22(1):457.

PMID: 36319975 PMC: 9628089. DOI: 10.1186/s12872-022-02881-6.


References
1.
Jain M, Wolf P . In vitro temperature map of cardiac ablation demonstrates the effect of flow on lesion development. Ann Biomed Eng. 2000; 28(9):1066-74. DOI: 10.1114/1.1310218. View

2.
Jain M, Wolf P . A three-dimensional finite element model of radiofrequency ablation with blood flow and its experimental validation. Ann Biomed Eng. 2000; 28(9):1075-84. DOI: 10.1114/1.1310219. View

3.
Tungjitkusolmun S, Vorperian V, Bhavaraju N, Cao H, TSAI J, Webster J . Guidelines for predicting lesion size at common endocardial locations during radio-frequency ablation. IEEE Trans Biomed Eng. 2001; 48(2):194-201. DOI: 10.1109/10.909640. View

4.
Fyrenius A, Wigstrom L, Ebbers T, Karlsson M, Engvall J, Bolger A . Three dimensional flow in the human left atrium. Heart. 2001; 86(4):448-55. PMC: 1729920. DOI: 10.1136/heart.86.4.448. View

5.
Demolin J, Eick O, Munch K, Koullick E, Nakagawa H, Wittkampf F . Soft thrombus formation in radiofrequency catheter ablation. Pacing Clin Electrophysiol. 2002; 25(8):1219-22. DOI: 10.1046/j.1460-9592.2002.01219.x. View