» Articles » PMID: 30607244

Self-contamination During Doffing of Personal Protective Equipment by Healthcare Workers to Prevent Ebola Transmission

Overview
Publisher Biomed Central
Date 2019 Jan 5
PMID 30607244
Citations 47
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Healthcare workers (HCWs) use personal protective equipment (PPE) in Ebola virus disease (EVD) situations. However, preventing the contamination of HCWs and the environment during PPE removal crucially requires improved strategies. This study aimed to compare the efficacy of three PPE ensembles, namely, Hospital Authority (HA) Standard Ebola PPE set (PPE1), Dupont Tyvek Model, style 1422A (PPE2), and HA isolation gown for routine patient care and performing aerosol-generating procedures (PPE3) to prevent EVD transmission by measuring the degree of contamination of HCWs and the environment.

Methods: A total of 59 participants randomly performed PPE donning and doffing. The trial consisted of PPE donning, applying fluorescent solution on the PPE surface, PPE doffing of participants, and estimation of the degree of contamination as indicated by the number of fluorescent stains on the working clothes and environment. Protocol deviations during PPE donning and doffing were monitored.

Results: PPE2 and PPE3 presented higher contamination risks than PPE1. Environmental contaminations such as those originating from rubbish bin covers, chairs, faucets, and sinks were detected. Procedure deviations were observed during PPE donning and doffing, with PPE1 presenting the lowest overall deviation rate (%) among the three PPE ensembles ( 0.05).

Conclusion: Contamination of the subjects' working clothes and surrounding environment occurred frequently during PPE doffing. Procedure deviations were observed during PPE donning and doffing. Although PPE1 presented a lower contamination risk than PPE2 and PPE3 during doffing and protocol deviations, the design of PPE1 can still be further improved. Future directions should focus on designing a high-coverage-area PPE with simple ergonomic features and on evaluating the doffing procedure to minimise the risk of recontamination. Regular training for users should be emphasised to minimise protocol deviations, and in turn, guarantee the best protection to HCWs.

Citing Articles

Is there sufficient evidence to inform personal protective equipment choices for healthcare workers caring for patients with viral hemorrhagic fevers?.

Graham A, Ettles S, McGrath M, Ogunremi T, Selkirk J, Bruce N Can Commun Dis Rep. 2025; 51(1):7-15.

PMID: 39781232 PMC: 11706576. DOI: 10.14745/ccdr.v51i01a02.


Protecting healthcare workers and patients during the COVID-19 pandemic: a comparison of baseline and follow-up infection prevention and control needs in Nigerian military healthcare facilities delivering HIV services.

Lee E, Rashid A, Lawal I, Adekanye U, Adamu Y, Godfrey C BMC Health Serv Res. 2023; 23(1):1254.

PMID: 37964245 PMC: 10647028. DOI: 10.1186/s12913-023-10289-x.


Impact of personal protective equipment on patient safety and health care workers.

Kumar P, Jain M, Amirthavaali G, Mishra T, Sasmal P, Lubaib K Med J Armed Forces India. 2023; 79(5):531-538.

PMID: 37719904 PMC: 10499652. DOI: 10.1016/j.mjafi.2021.07.004.


Assessment of Role of PPE in Preventing the Spread of Infection among the Dental Surgeons: A Prospective Study.

Srinidhi S, Stephen S, Mohankumar K, DCruz T, Subbiah K, Subbiah G J Pharm Bioallied Sci. 2023; 15(Suppl 1):S362-S366.

PMID: 37654383 PMC: 10466661. DOI: 10.4103/jpbs.jpbs_546_22.


COVID-19-specific adult basic life support guideline strategies for chiropractors and other healthcare providers to maximize the safety and efficacy of resuscitation: a commentary.

Woo C Chiropr Man Therap. 2023; 31(1):16.

PMID: 37277875 PMC: 10241126. DOI: 10.1186/s12998-023-00488-y.


References
1.
Kang J, ODonnell J, Colaianne B, Bircher N, Ren D, Smith K . Use of personal protective equipment among health care personnel: Results of clinical observations and simulations. Am J Infect Control. 2017; 45(1):17-23. DOI: 10.1016/j.ajic.2016.08.011. View

2.
Casanova L, Teal L, Sickbert-Bennett E, Anderson D, Sexton D, Rutala W . Assessment of Self-Contamination During Removal of Personal Protective Equipment for Ebola Patient Care. Infect Control Hosp Epidemiol. 2016; 37(10):1156-61. DOI: 10.1017/ice.2016.169. View

3.
Casanova L, Alfano-Sobsey E, Rutala W, Weber D, Sobsey M . Virus transfer from personal protective equipment to healthcare employees' skin and clothing. Emerg Infect Dis. 2008; 14(8):1291-3. PMC: 2600382. DOI: 10.3201/eid1408.080085. View

4.
Bell T, Smoot J, Patterson J, Smalligan R, Jordan R . Ebola virus disease: The use of fluorescents as markers of contamination for personal protective equipment. IDCases. 2016; 2(1):27-30. PMC: 4672605. DOI: 10.1016/j.idcr.2014.12.003. View

5.
Kwon J, Burnham C, Reske K, Liang S, Hink T, Wallace M . Assessment of Healthcare Worker Protocol Deviations and Self-Contamination During Personal Protective Equipment Donning and Doffing. Infect Control Hosp Epidemiol. 2017; 38(9):1077-1083. PMC: 6263164. DOI: 10.1017/ice.2017.121. View