Novel Tailoring Algorithm for Abrupt Motion Artifact Removal in Photoplethysmogram Signals

Overview
Journal Biomed Eng Lett
Date 2019 Jan 4
PMID 30603179
Citations 1
Authors
Affiliations
Soon will be listed here.
Abstract

Photoplethysmogram (PPG) signals are widely used for wearable electronic devices nowadays. The PPG signal is extremely sensitive to the motion artifacts (MAs) caused by the subject's movement. The detection and removal of such MAs remains a difficult problem. Due to the complicated MA signal waveforms, none of the existing techniques can lead to satisfactory results. In this paper, a new framework to identify and tailor the abrupt MAs in PPG is proposed, which consists of feature extraction, change-point detection, and MA removal. In order to achieve the optimal performance, a data-dependent frame-size determination mechanism is employed. Experiments for the heart-beat-rate-measurement application have been conducted to demonstrate the effectiveness of our proposed method, by a correct detection rate of MAs at 98% and the average heart-beat-rate tracking accuracy above 97%. On the other hand, this new framework maintains the original signal temporal structure unlike the spectrum-based approach, and it can be further applied for the calculation of blood oxygen level (SpO).

Citing Articles

Integrating Physiological Data Artifacts Detection With Clinical Decision Support Systems: Observational Study.

Nizami S, McGregor Am C, Green J JMIR Biomed Eng. 2024; 6(2):e23495.

PMID: 38907382 PMC: 11041468. DOI: 10.2196/23495.

References
1.
Kim B, Yoo S . Motion artifact reduction in photoplethysmography using independent component analysis. IEEE Trans Biomed Eng. 2006; 53(3):566-8. DOI: 10.1109/TBME.2005.869784. View

2.
Wu H, Gupta N, Mylavarapu P . Blind multiridge detection for automatic nondestructive testing using ultrasonic signals. IEEE Trans Ultrason Ferroelectr Freq Control. 2006; 53(10):1902-11. DOI: 10.1109/tuffc.2006.123. View

3.
Yao J, Warren S . A short study to assess the potential of independent component analysis for motion artifact separation in wearable pulse oximeter signals. Conf Proc IEEE Eng Med Biol Soc. 2007; 2005:3585-8. DOI: 10.1109/IEMBS.2005.1617256. View

4.
Allen J . Photoplethysmography and its application in clinical physiological measurement. Physiol Meas. 2007; 28(3):R1-39. DOI: 10.1088/0967-3334/28/3/R01. View

5.
Krishnan R, Natarajan B, Warren S . Two-stage approach for detection and reduction of motion artifacts in photoplethysmographic data. IEEE Trans Biomed Eng. 2010; 57(8):1867-76. DOI: 10.1109/TBME.2009.2039568. View