Ultra-Low-Dose F-Florbetaben Amyloid PET Imaging Using Deep Learning with Multi-Contrast MRI Inputs

Abstract

Purpose To reduce radiotracer requirements for amyloid PET/MRI without sacrificing diagnostic quality by using deep learning methods. Materials and Methods Forty data sets from 39 patients (mean age ± standard deviation [SD], 67 years ± 8), including 16 male patients and 23 female patients (mean age, 66 years ± 6 and 68 years ± 9, respectively), who underwent simultaneous amyloid (fluorine 18 [F]-florbetaben) PET/MRI examinations were acquired from March 2016 through October 2017 and retrospectively analyzed. One hundredth of the raw list-mode PET data were randomly chosen to simulate a low-dose (1%) acquisition. Convolutional neural networks were implemented with low-dose PET and multiple MR images (PET-plus-MR model) or with low-dose PET alone (PET-only) as inputs to predict full-dose PET images. Quality of the synthesized images was evaluated while Bland-Altman plots assessed the agreement of regional standard uptake value ratios (SUVRs) between image types. Two readers scored image quality on a five-point scale (5 = excellent) and determined amyloid status (positive or negative). Statistical analyses were carried out to assess the difference of image quality metrics and reader agreement and to determine confidence intervals (CIs) for reading results. Results The synthesized images (especially from the PET-plus-MR model) showed marked improvement on all quality metrics compared with the low-dose image. All PET-plus-MR images scored 3 or higher, with proportions of images rated greater than 3 similar to those for the full-dose images (-10% difference [eight of 80 readings], 95% CI: -15%, -5%). Accuracy for amyloid status was high (71 of 80 readings [89%]) and similar to intrareader reproducibility of full-dose images (73 of 80 [91%]). The PET-plus-MR model also had the smallest mean and variance for SUVR difference to full-dose images. Conclusion Simultaneously acquired MRI and ultra-low-dose PET data can be used to synthesize full-dose-like amyloid PET images. © RSNA, 2018 Online supplemental material is available for this article. See also the editorial by Catana in this issue.

Citing Articles

Data-efficient generalization of AI transformers for noise reduction in ultra-fast lung PET scans.

Wang J, Zhang X, Miao Y, Xue S, Zhang Y, Shi K Eur J Nucl Med Mol Imaging. 2025; .

PMID: 40009163 DOI: 10.1007/s00259-025-07165-7.


Diffused Multi-scale Generative Adversarial Network for low-dose PET images reconstruction.

Yu X, Hu D, Yao Q, Fu Y, Zhong Y, Wang J Biomed Eng Online. 2025; 24(1):16.

PMID: 39924498 PMC: 11807330. DOI: 10.1186/s12938-025-01348-x.


Robust whole-body PET image denoising using 3D diffusion models: evaluation across various scanners, tracers, and dose levels.

Yu B, Ozdemir S, Dong Y, Shao W, Pan T, Shi K Eur J Nucl Med Mol Imaging. 2025; .

PMID: 39912940 DOI: 10.1007/s00259-025-07122-4.


Non-parametric Bayesian deep learning approach for whole-body low-dose PET reconstruction and uncertainty assessment.

Levital M, Khawaled S, Kennedy J, Freiman M Med Biol Eng Comput. 2025; .

PMID: 39847156 DOI: 10.1007/s11517-025-03296-z.


Developing a Research Center for Artificial Intelligence in Medicine.

Langlotz C, Kim J, Shah N, Lungren M, Larson D, Datta S Mayo Clin Proc Digit Health. 2025; 2(4):677-686.

PMID: 39802660 PMC: 11720458. DOI: 10.1016/j.mcpdig.2024.07.005.


References
1.
Berti V, Pupi A, Mosconi L . PET/CT in diagnosis of dementia. Ann N Y Acad Sci. 2011; 1228:81-92. PMC: 3692287. DOI: 10.1111/j.1749-6632.2011.06015.x. View

2.
Pichler B, Kolb A, Nagele T, Schlemmer H . PET/MRI: paving the way for the next generation of clinical multimodality imaging applications. J Nucl Med. 2010; 51(3):333-6. DOI: 10.2967/jnumed.109.061853. View

3.
Gatidis S, Wurslin C, Seith F, Schafer J, Fougere C, Nikolaou K . Towards tracer dose reduction in PET studies: Simulation of dose reduction by retrospective randomized undersampling of list-mode data. Hell J Nucl Med. 2016; 19(1):15-8. DOI: 10.1967/s002449910333. View

4.
Catana C, Benner T, van der Kouwe A, Byars L, Hamm M, Chonde D . MRI-assisted PET motion correction for neurologic studies in an integrated MR-PET scanner. J Nucl Med. 2010; 52(1):154-61. PMC: 3125596. DOI: 10.2967/jnumed.110.079343. View

5.
Xiang L, Qiao Y, Nie D, An L, Wang Q, Shen D . Deep Auto-context Convolutional Neural Networks for Standard-Dose PET Image Estimation from Low-Dose PET/MRI. Neurocomputing (Amst). 2017; 267:406-416. PMC: 5714510. DOI: 10.1016/j.neucom.2017.06.048. View