» Articles » PMID: 30510289

Efficacy of Engineered GO Amberlite XAD-16 Picolylamine Sorbent for the Trace Determination of Pb (II) and Cu (II) in Fishes by Solid Phase Extraction Column Coupled with Inductively Coupled Plasma Optical Emission Spectrometry

Overview
Journal Sci Rep
Specialty Science
Date 2018 Dec 5
PMID 30510289
Citations 7
Authors
Affiliations
Soon will be listed here.
Abstract

Graphene oxide (GO) was immobilized innovatively through azo spacer arm onto the surface of polymeric Amberlite XAD-16 resin in order to expose all oxygen functionalities freely available for metal ions coordination and further modification with picolylamine which governs selectivity. The GO Amberlite XAD-16 picolylamine enables the development of SPE column coupled with ICP-OES for preconcentration and determination of Pb (II) and Cu (II) in water and fish samples. Elution was performed by mild acid (2M HCl) no other carcinogenic organic solvent was used, prevents ligand leaching. Under optimized conditions, the preconcentration factors of 150 and detection limits 1.434 and 0.048 µg L for Pb (II) and Cu (II)  were obtained respectively.

Citing Articles

Histological and Chemical Analysis of Heavy Metals in Kidney and Gills of : Melanomacrophages Centers and Rodlet Cells as Environmental Biomarkers.

Alesci A, Cicero N, Fumia A, Petrarca C, Mangifesta R, Nava V Toxics. 2022; 10(5).

PMID: 35622632 PMC: 9147125. DOI: 10.3390/toxics10050218.


Water quality index, , and : Suitable bio-indicators of river water pollution.

Tabrez S, Zughaibi T, Javed M Saudi J Biol Sci. 2022; 29(1):75-82.

PMID: 35002395 PMC: 8717156. DOI: 10.1016/j.sjbs.2021.10.052.


[Recent advances in sample preparation technologies for analysis of harmful substances in aquatic products].

Wang X, Chen Y, Xiao X, Li G Se Pu. 2021; 39(1):34-45.

PMID: 34227357 PMC: 9274841. DOI: 10.3724/SP.J.1123.2020.07025.


Enhanced Turn-On Fluorescence Detection of Aqueous Lead Ions with Size-Shrinkable Hydrogels.

Zheng Y, Li Q, Wang C, Su M ACS Omega. 2021; 6(18):11897-11901.

PMID: 34056343 PMC: 8154013. DOI: 10.1021/acsomega.1c00150.


Bioaccumulation of heavy metals and their toxicity assessment in species.

Tabrez S, Zughaibi T, Javed M Saudi J Biol Sci. 2021; 28(2):1459-1464.

PMID: 33613073 PMC: 7878687. DOI: 10.1016/j.sjbs.2020.11.085.


References
1.
Xu H, Wu Y, Wang J, Shang X, Jiang X . Simultaneous preconcentration of cadmium and lead in water samples with silica gel and determination by flame atomic absorption spectrometry. J Environ Sci (China). 2014; 25 Suppl 1:S45-9. DOI: 10.1016/S1001-0742(14)60624-0. View

2.
Scida K, Stege P, Haby G, Messina G, Garcia C . Recent applications of carbon-based nanomaterials in analytical chemistry: critical review. Anal Chim Acta. 2011; 691(1-2):6-17. PMC: 3088727. DOI: 10.1016/j.aca.2011.02.025. View

3.
Sitko R, Zawisza B, Talik E, Janik P, Osoba G, Feist B . Spherical silica particles decorated with graphene oxide nanosheets as a new sorbent in inorganic trace analysis. Anal Chim Acta. 2014; 834:22-9. DOI: 10.1016/j.aca.2014.05.014. View

4.
Islam A, Ahmad H, Zaidi N, Kumar S . Graphene oxide sheets immobilized polystyrene for column preconcentration and sensitive determination of lead by flame atomic absorption spectrometry. ACS Appl Mater Interfaces. 2014; 6(15):13257-65. DOI: 10.1021/am5031215. View

5.
He Q, Hu Z, Jiang Y, Chang X, Tu Z, Zhang L . Preconcentration of Cu(II), Fe(III) and Pb(II) with 2-((2-aminoethylamino)methyl)phenol-functionalized activated carbon followed by ICP-OES determination. J Hazard Mater. 2009; 175(1-3):710-4. DOI: 10.1016/j.jhazmat.2009.10.067. View