» Articles » PMID: 24439501

A Self-assembly Pipette Tip Graphene Solid-phase Extraction Coupled with Liquid Chromatography for the Determination of Three Sulfonamides in Environmental Water

Overview
Journal Anal Chim Acta
Publisher Elsevier
Specialty Chemistry
Date 2014 Jan 21
PMID 24439501
Citations 7
Authors
Affiliations
Soon will be listed here.
Abstract

A sensitive, economical, and miniaturized self-assembly pipette tip graphene solid-phase extraction (PT-G-SPE) coupled with liquid chromatography fluorescence detection (LC-FD) was developed for rapid extraction and determination of three sulfonamide antibiotics (SAs) in environmental water samples. The PT-G-SPE cartridge, assembled by packing 1.0mg of graphene as sorbent into a 100μL pipette tip, showed high adsorption capacity for the SAs owing to the large surface area and unique structure of graphene. The factors that affected the extraction efficiency of PT-G-SPE, including sample volume, pH, sorbent amount, washing solvent and eluent solvent were optimized. Good linearity for SAs was obtained in a range of 2-4000pgmL(-1) with correlation coefficients (r(2))≥0.9993. The recoveries of the SAs at three spiked levels ranged from 90.4% to 108.2% with relative standard deviations (RSD)≤6.3%. In comparison with other sorbents such as C18, HLB, SCX, PCX, and multiwalled carbon nanotubes, one advantage of using graphene as sorbent of pipette tip solid-phase extraction (PT-SPE) was that PT-G-SPE could adsorb larger sample volume (10mL) at a small amount of sorbent (1mg) and low solvent consumption with good extraction efficiency, which not only increased the fraction of analytes to LC and the sensitivity of SAs determination, but also reduced the cost and pollution.

Citing Articles

Recent advances in micro- and nanomaterial-based adsorbents for pipette-tip solid-phase extraction.

Sun H, Feng J, Han S, Ji X, Li C, Feng J Mikrochim Acta. 2021; 188(6):189.

PMID: 33991231 DOI: 10.1007/s00604-021-04806-0.


Molybdenum disulfide-hypercrosslinked polymer composite as an adsorbent for determination of polycyclic aromatic hydrocarbons in environmental water coupled with HPLC-FLD.

Li L, Han D, Wang M, Han Y, Yan H Mikrochim Acta. 2020; 187(4):242.

PMID: 32206906 DOI: 10.1007/s00604-020-4220-0.


Application of response surface methodology for optimization of metal-organic framework based pipette-tip solid phase extraction of organic dyes from seawater and their determination with HPLC.

Hashemi S, Kaykhaii M, Jamali Keikha A, Mirmoradzehi E, Sargazi G BMC Chem. 2019; 13(1):59.

PMID: 31384807 PMC: 6661774. DOI: 10.1186/s13065-019-0572-0.


A hybrid material prepared by controlled growth of a covalent organic framework on amino-modified MIL-68 for pipette tip solid-phase extraction of sulfonamides prior to their determination by HPLC.

Chen Z, Yu C, Xi J, Tang S, Bao T, Zhang J Mikrochim Acta. 2019; 186(6):393.

PMID: 31152235 DOI: 10.1007/s00604-019-3513-7.


Efficacy of engineered GO Amberlite XAD-16 picolylamine sorbent for the trace determination of Pb (II) and Cu (II) in fishes by solid phase extraction column coupled with inductively coupled plasma optical emission spectrometry.

Javed H, Islam A, Chauhan A, Kumar S, Kumar S Sci Rep. 2018; 8(1):17560.

PMID: 30510289 PMC: 6277385. DOI: 10.1038/s41598-018-35656-1.