Abstract

Hemorheological properties such as viscosity, deformability, and aggregation have been employed to monitor or screen patients with cardiovascular diseases. To effectively evaluate blood circulating within an in vitro closed circuit, it is important to quantify its hemorheological properties consistently and accurately. A simple method for measuring red blood cell (RBC) aggregation and blood viscosity is proposed for analyzing blood flow in a microfluidic device, especially in a continuous and simultaneous fashion. To measure RBC aggregation, blood flows through three channels: the left wide channel, the narrow channel and the right wide channel sequentially. After quantifying the image intensity of RBCs aggregated in the left channel (<I>) and the RBCs disaggregated in the right channel (<I>), the RBC aggregation index (AI) is obtained by dividing <I> by <I>. Simultaneously, based on a modified parallel flow method, blood viscosity is obtained by detecting the interface between two fluids in the right wide channel. RBC aggregation and blood viscosity were first evaluated under constant and pulsatile blood flows. AI varies significantly with respect to blood flow rate (for both its amplitude and period) and the concentration of the dextran solution used. According to our quantitative comparison between the proposed aggregation index (AI) and the conventional aggregation index (AI), it is found that AI provides consistent results. Finally, the suggested method is employed to obtain the RBC aggregation and blood viscosity of blood circulating within an in vitro fluidic circuit. The experimental results lead to the conclusion that the proposed method can be successfully used to measure RBC aggregation and blood viscosity, especially in a continuous and simultaneous fashion.

Citing Articles

Advances in Microfluidics for Single Red Blood Cell Analysis.

Grigorev G, Lebedev A, Wang X, Qian X, Maksimov G, Lin L Biosensors (Basel). 2023; 13(1).

PMID: 36671952 PMC: 9856164. DOI: 10.3390/bios13010117.


Biosensing of Haemorheological Properties Using Microblood Flow Manipulation and Quantification.

Kang Y Sensors (Basel). 2023; 23(1).

PMID: 36617006 PMC: 9823650. DOI: 10.3390/s23010408.


Persistent red blood cells retain their ability to move in microcapillaries under high levels of oxidative stress.

Besedina N, Skverchinskaya E, Shmakov S, Ivanov A, Mindukshev I, Bukatin A Commun Biol. 2022; 5(1):659.

PMID: 35787676 PMC: 9253111. DOI: 10.1038/s42003-022-03620-5.


Microfluidics Approach to the Mechanical Properties of Red Blood Cell Membrane and Their Effect on Blood Rheology.

Trejo-Soto C, Lazaro G, Pagonabarraga I, Hernandez-Machado A Membranes (Basel). 2022; 12(2).

PMID: 35207138 PMC: 8878405. DOI: 10.3390/membranes12020217.


Ultrasound Standing Wave-Based Cell-to-liquid Separation for Measuring Viscosity and Aggregation of Blood Sample.

Kim G, Jeong S, Kang Y Sensors (Basel). 2020; 20(8).

PMID: 32316446 PMC: 7219585. DOI: 10.3390/s20082284.


References
1.
Kang Y . Periodic and simultaneous quantification of blood viscosity and red blood cell aggregation using a microfluidic platform under closed-loop circulation. Biomicrofluidics. 2018; 12(2):024116. PMC: 5891346. DOI: 10.1063/1.5017052. View

2.
Kang Y, Ha Y, Lee S . High-Throughput and Label-Free Blood-on-a-Chip for Malaria Diagnosis. Anal Chem. 2016; 88(5):2912-22. DOI: 10.1021/acs.analchem.5b04874. View

3.
Kang Y, Yeom E, Seo E, Lee S . Bubble-free and pulse-free fluid delivery into microfluidic devices. Biomicrofluidics. 2014; 8(1):014102. PMC: 3982455. DOI: 10.1063/1.4863355. View

4.
Kang Y, Kim M, Son K, Lim C, Son H, Yoon S . Experimental investigation of pulsatility effect on the deformability and hemolysis of blood cells. Artif Organs. 2010; 34(4):E103-9. DOI: 10.1111/j.1525-1594.2009.00974.x. View

5.
Srivastava N, Burns M . Analysis of non-Newtonian liquids using a microfluidic capillary viscometer. Anal Chem. 2006; 78(5):1690-6. DOI: 10.1021/ac0518046. View