Optical and Visual Quality After Small-incision Lenticule Extraction

Overview
Specialty Ophthalmology
Date 2018 Nov 5
PMID 30391154
Citations 19
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: To examine the relationship between corneal higher-order aberrations (HOAs), scatter, and residual refraction with visual symptoms and visual acuity after small-incision lenticule extraction (SMILE) for myopia and astigmatism.

Setting: University Eye Clinic, Aarhus, Denmark.

Design: Prospective case series.

Methods: Eyes had small-incision lenticule extraction for myopia or myopic astigmatism. Examinations were performed preoperatively and 1 day, 7 days, 1 month, and 3 months postoperatively and included subjective refraction, Pentacam HR measurements, scatter measurements (objective scatter index [OSI]), and questionnaires on visual quality and symptoms.

Results: The mean preoperative spherical equivalent (SE) was -7.08 diopters (D) ± 1.17 (SD). At 3 months, the mean uncorrected distance visual acuity (UDVA) was -0.03 ± 0.11 logarithm of the minimum angle of resolution and the mean SE, -0.17 ± 0.33 D; the OSI increased by a mean of 0.22 ± 0.53 (P = .06) and coma by 0.1 ± 0.1 μm (P < .001); spherical aberration did not change significantly. The severity of self-reported visual symptoms decreased postoperatively. Scatter, corneal HOAs, and residual refraction were not correlated with the degree of visual symptoms. On linear regression analysis, residual refraction was a significant predictor of UDVA (1 day: adjusted R = 0.16, P = .02; 3 months: adjusted R = 0.55, P < .001). Scatter and corneal HOAs were not associated with postoperative UDVA.

Conclusions: Despite statistically significant changes in scatter and corneal HOAs, the severity of self-reported visual symptoms decreased postoperatively. Residual refraction was a good predictor of postoperative UDVA. Scatter and corneal HOAs had no effect on the postoperative UDVA.

Citing Articles

SMILE for correction of myopia in patients during the incipient phase of presbyopia.

Zhang R, Zhao X, Yuan Y, Zhang Y, Chen Y Int Ophthalmol. 2025; 45(1):50.

PMID: 39881018 DOI: 10.1007/s10792-025-03427-3.


The Effect of 0.05D Interval Precise Refraction on Small-Incision Lenticule Extraction Surgery: A Retrospective Study with Short-Term Follow-Up.

Li J, Zhen J, Xie K, Yao K, Liu Z, Li X Clin Optom (Auckl). 2024; 16():341-348.

PMID: 39735413 PMC: 11682664. DOI: 10.2147/OPTO.S485270.


Posterior lenticule laser scan influence the ultra-early postoperative visual acuity and quality of SMILE.

Wan Q, Qian T, Wei R, Yin H, Tang J, Ma K Sci Rep. 2024; 14(1):27072.

PMID: 39511370 PMC: 11544260. DOI: 10.1038/s41598-024-78080-4.


Comparison of objective visual quality between SMILE and FS-LASIK in moderate-to-high myopia.

Zou H, Wei X, Li L, Wei D, Mao H, Huang Y Front Med (Lausanne). 2024; 11:1408516.

PMID: 39359915 PMC: 11446171. DOI: 10.3389/fmed.2024.1408516.


Compound electrolyte intraocular irrigating solution produces better effects on vision recovery of cataract patients after surgery than Ringer lactate solution.

Guo C, Tian F, Ren D, Gao Y, Wang T Int Ophthalmol. 2024; 44(1):233.

PMID: 38886282 DOI: 10.1007/s10792-024-03131-8.