Objective: The aim of this study was to investigate the quantitative and qualitative effects of virtual monoenergetic images (VMI) by spectral detector computed tomography (SDCT) on calcium blooming in coronary computed tomography angiography.

Methods: Coronary computed tomography angiography using SDCT was performed on 42 patients with coronary artery calcifications. Stenosis grading by diameter and area of calcified plaques and free lumen using VMI from 70 to 140 keV was performed and compared with measurements by conventional images. In addition, interobserver reliability and subjective image quality were assessed by 2 experienced readers.

Results: A total of 61 coronary arteries were evaluated. Stenosis grading by diameter and area showed significant incremental decrease, from 48.86% to 22.82% and from 41.18% to 11.33%, respectively, with increasing VMI (P < 0.05). Interobserver reliability was excellent (intraclass correlation coefficient >0.99). Overall image quality was best at 80 keV.

Conclusions: Calcium blooming significantly decreases at higher monoenergetic levels from SDCT, increasing luminal dimensions and decreasing stenotic grading, with best overall subjective image quality using 80-keV VMI.

Citing Articles

Spectral quantification in different lumen diameters for cardiovascular applications.

Liu L, Rybertt M, Pasyar P, Shapira N, Litt H, Noel P Conf Proc Int Conf Image Form Xray Comput Tomogr. 2025; 2024:356-359.

PMID: 39925379 PMC: 11807396.


Multienergy cardiovascular CT imaging: current state and future.

Klambauer K, Lisi C, Moser L, Mergen V, Flohr T, Eberhard M Br J Radiol. 2024; 98(1167):321-329.

PMID: 39656967 PMC: 11840172. DOI: 10.1093/bjr/tqae246.


Monoenergetic reconstructions and iodine density maps for visualization of coronary artery stents using 8-cm dual-layer detector spectral computed tomography: an phantom study.

Chen L, Pan N, Hu B, Li Y, Dong S, Zhou Y Quant Imaging Med Surg. 2024; 14(10):7671-7683.

PMID: 39429615 PMC: 11485354. DOI: 10.21037/qims-24-786.


Computed Tomography in Infectious Endocarditis.

Dalebout E, Hirsch A, Kluin J, Galema T, Roos-Hesselink J, Budde R J Soc Cardiovasc Angiogr Interv. 2024; 3(3Part B):101292.

PMID: 39131217 PMC: 11308100. DOI: 10.1016/j.jscai.2023.101292.


Diagnostic Efficacy and Safety of Low-Contrast-Dose Dual-Energy CT in Patients With Renal Impairment Undergoing Transcatheter Aortic Valve Replacement.

Chang S, Jung J, Beck K, Chang K, Kim Y, Han K Korean J Radiol. 2024; 25(7):634-643.

PMID: 38942457 PMC: 11214918. DOI: 10.3348/kjr.2023.1207.