» Articles » PMID: 30327638

Disability Adjusted Life Years Due to Ischaemic Stroke Preventable by Real-Time Stroke Detection-A Cost-Utility Analysis of Hypothetical Stroke Detection Devices

Overview
Journal Front Neurol
Specialty Neurology
Date 2018 Oct 18
PMID 30327638
Citations 3
Authors
Affiliations
Soon will be listed here.
Abstract

Ischaemic stroke remains a significant contributor to permanent disability world-wide. Therapeutic interventions for acute ischaemic stroke (AIS) are available, but need to be administered early after symptom onset in order to be effective. Currently, one of the main factors responsible for poor clinical outcome is an unnecessary long time between symptom onset and arrival at a hospital (pre-hospital delay). In the future, technological devices with the capability of real-time detection of AIS may become available. The health economic implications of such devices have not been explored. We developed a novel probabilistic model to estimate the maximally allowable annual costs of different hypothetical real-time AIS detection devices in different populations given currently accepted willingness-to-pay thresholds. Distributions of model parameters were extracted from the literature. Effectiveness of the intervention was quantified as reduction in disability-adjusted life-years associated with faster access to thrombolysis and mechanical thrombectomy. Incremental costs were calculated from a societal perspective including acute treatment costs and long-term costs for nursing care, home help, and loss of production. The impact of individual model parameters was explored in one-way and multi-way sensitivity analyses. The model yields significantly shorter prehospital delays and a higher proportion of acute ischaemic patients that fulfill the time-based eligibility criteria for thrombolysis or mechanical thrombectomy in the scenario with a real-time stroke detection device as compared to the control scenario. Depending on the sociodemographic and geographic characteristics of the study population and operating characteristics of the device, the maximally allowable annual cost for the device to operate in a cost-effective manner assuming a willingness-to-pay threshold of GBP 30.000 ranges from GBP 22.00 to GBP 9,952.00. Considering the results of multiway sensitivity analyses, the upper bound increases to GBP 29,449.10 in the subgroup of young patients with a very high annual risk of ischaemic stroke (50 years/20% annual risk). Data from probabilistic modeling suggest that real-time AIS detection devices can be expected to be cost-effective only for a small group of highly selected individuals.

Citing Articles

Association of Neighborhood-Level Socioeconomic Factors With Delay to Hospital Arrival in Patients With Acute Stroke.

Forman R, Okumu R, Mageid R, Baker A, Neu D, Parker R Neurology. 2024; 102(1):e207764.

PMID: 38165368 PMC: 10834135. DOI: 10.1212/WNL.0000000000207764.


Frequency of Aspirin Resistance in Ischemic Stroke Patients and Healthy Controls from Colombia.

Roman-Gonzalez A, Naranjo C, Cardona-Maya W, Vallejo D, Garcia F, Franco C Stroke Res Treat. 2021; 2021:9924710.

PMID: 34094500 PMC: 8164531. DOI: 10.1155/2021/9924710.


Improving timely treatment with a stroke emergency map: The case of northern China.

Zhang T, Zhang X, Sun H, Zhou F, Lin S, Sang H Brain Behav. 2020; 10(8):e01743.

PMID: 32652889 PMC: 7428498. DOI: 10.1002/brb3.1743.

References
1.
Steen Carlsson K, Andsberg G, Petersson J, Norrving B . Long-term cost-effectiveness of thrombectomy for acute ischaemic stroke in real life: An analysis based on data from the Swedish Stroke Register (Riksstroke). Int J Stroke. 2017; 12(8):802-814. DOI: 10.1177/1747493017701154. View

2.
Vanacker P, Heldner M, Amiguet M, Faouzi M, Cras P, Ntaios G . Prediction of Large Vessel Occlusions in Acute Stroke: National Institute of Health Stroke Scale Is Hard to Beat. Crit Care Med. 2016; 44(6):e336-43. DOI: 10.1097/CCM.0000000000001630. View

3.
Meretoja A, Keshtkaran M, Saver J, Tatlisumak T, Parsons M, Kaste M . Stroke thrombolysis: save a minute, save a day. Stroke. 2014; 45(4):1053-8. DOI: 10.1161/STROKEAHA.113.002910. View

4.
Crane J, Hakim N . The use of an implantable Doppler flow probe in kidney transplantation: first report in the literature. Exp Clin Transplant. 2011; 9(2):118-20. View

5.
Ao D, Sun R, Song R . Comparison of complexity of EMG signals between a normal subject and a patient after stroke--a case study. Annu Int Conf IEEE Eng Med Biol Soc. 2013; 2013:4965-8. DOI: 10.1109/EMBC.2013.6610662. View