» Articles » PMID: 30278389

Automated EEG Source Imaging: A Retrospective, Blinded Clinical Validation Study

Overview
Publisher Elsevier
Specialties Neurology
Psychiatry
Date 2018 Oct 3
PMID 30278389
Citations 17
Authors
Affiliations
Soon will be listed here.
Abstract

Objective: To evaluate the accuracy of automated EEG source imaging (ESI) in localizing epileptogenic zone.

Methods: Long-term EEG, recorded with the standard 25-electrode array of the IFCN, from 41 consecutive patients with focal epilepsy who underwent resective surgery, were analyzed blinded to the surgical outcome. The automated analysis comprised spike-detection, clustering and source imaging at the half-rising time and at the peak of each spike-cluster, using individual head-models with six tissue-layers and a distributed source model (sLORETA). The fully automated approach presented ESI of the cluster with the highest number of spikes, at the half-rising time. In addition, a physician involved in the presurgical evaluation of the patients, evaluated the automated ESI results (up to four clusters per patient) in clinical context and selected the dominant cluster and the analysis time-point (semi-automated approach). The reference standard was location of the resected area and outcome one year after operation.

Results: Accuracy was 61% (95% CI: 45-76%) for the fully automated approach and 78% (95% CI: 62-89%) for the semi-automated approach.

Conclusion: Automated ESI has an accuracy similar to previously reported neuroimaging methods.

Significance: Automated ESI will contribute to increased utilization of source imaging in the presurgical evaluation of patients with epilepsy.

Citing Articles

Spike-spindle coupling during sleep and its mechanism explanation in childhood focal epilepsy.

Pan M, Li Q, Song J, Li D, Zhang R Cogn Neurodyn. 2024; 18(5):2145-2160.

PMID: 39555302 PMC: 11564472. DOI: 10.1007/s11571-023-10052-2.


Quantitative EEG biomarkers for STXBP1-related disorders.

Cossu A, Furia F, Proietti J, Ancora C, Reale C, Darra F Epilepsia. 2024; 65(12):3595-3606.

PMID: 39463124 PMC: 11647438. DOI: 10.1111/epi.18154.


Brain health in diverse settings: How age, demographics and cognition shape brain function.

Hernandez H, Baez S, Medel V, Moguilner S, Cuadros J, Santamaria-Garcia H Neuroimage. 2024; 295:120636.

PMID: 38777219 PMC: 11812057. DOI: 10.1016/j.neuroimage.2024.120636.


Yield of non-invasive imaging in MRI-negative focal epilepsy.

Czarnetzki C, Spinelli L, Huppertz H, Schaller K, Momjian S, Lobrinus J J Neurol. 2023; 271(2):995-1003.

PMID: 37907727 PMC: 10827933. DOI: 10.1007/s00415-023-11987-6.


Electromagnetic source imaging predicts surgical outcome in children with focal cortical dysplasia.

Chikara R, Jahromi S, Tamilia E, Madsen J, Stufflebeam S, Pearl P Clin Neurophysiol. 2023; 153:88-101.

PMID: 37473485 PMC: 10528204. DOI: 10.1016/j.clinph.2023.06.015.