Flexible Freestanding Graphene Paper-based Potentiometric Enzymatic Aptasensor for Ultrasensitive Wireless Detection of Kanamycin

Overview
Date 2018 Sep 4
PMID 30174273
Citations 14
Authors
Affiliations
Soon will be listed here.
Abstract

Flexible sensing devices have drawn tremendous attention in the past decades due to their potential applications in future hand-held, potable consumer, and wearable electronics. Here, we firstly developed an ultrasensitive wireless potentiometric aptasensor based on flexible freestanding graphene paper for kanamycin detection. Flexible graphene paper made from a simple vacuum filtration method was used as a biocompatible platform for effective immobilization of aptamer. A nuclease-assisted amplification strategy was introduced into this potentiometric biosensing system in order to significantly improve the detection sensitivity through a classic catalytic recycling reaction of target induced by the nuclease (DNase I). As expected, an ultra-low detection limit of 30.0 fg/mL for kanamycin was achieved. Furthermore, the developed potentiometric enzymatic aptasensor exhibits high selectivity, favorable flexibility, excellent stability and reproducibility, which holds great promising for its routine sensing application.

Citing Articles

Perspectives in Aptasensor-Based Portable Detection for Biotoxins.

Li C, Zhu Z, Yao J, Chen Z, Huang Y Molecules. 2024; 29(20).

PMID: 39459259 PMC: 11510259. DOI: 10.3390/molecules29204891.


Lattice matching enables construction of CaS@NaYF heterostructure with synergistically enhanced water resistance and luminescence for antibiotic detection.

Wang Y, Chen H, Zhao T, Wang J, Wu Y, Liu J Mikrochim Acta. 2024; 191(8):485.

PMID: 39060720 DOI: 10.1007/s00604-024-06568-x.


Paper-Based Aptasensors: Working Principles, Detection Modes, and Applications.

Economou A, Kokkinos C, Bousiakou L, Hianik T Sensors (Basel). 2023; 23(18).

PMID: 37765843 PMC: 10536119. DOI: 10.3390/s23187786.


Advancement in Paper-Based Electrochemical Biosensing and Emerging Diagnostic Methods.

Benjamin S, de Lima F, do Nascimento V, de Andrade G, Barreto Oria R Biosensors (Basel). 2023; 13(7).

PMID: 37504088 PMC: 10377443. DOI: 10.3390/bios13070689.


Trends in Paper-Based Sensing Devices for Clinical and Environmental Monitoring.

Kummari S, Panicker L, Rao Bommi J, Karingula S, Sunil Kumar V, Mahato K Biosensors (Basel). 2023; 13(4).

PMID: 37185495 PMC: 10135896. DOI: 10.3390/bios13040420.