Estimating the Uncertainty of Calculated Out-of-field Organ Dose from a Commercial Treatment Planning System

Overview
Date 2018 Jun 14
PMID 29896876
Citations 4
Authors
Affiliations
Soon will be listed here.
Abstract

Therapeutic radiation to cancer patients is accompanied by unintended radiation to organs outside the treatment field. It is known that the model-based dose algorithm has limitation in calculating the out-of-field doses. This study evaluated the out-of-field dose calculated by the Varian Eclipse treatment planning system (v.11 with AAA algorithm) in realistic treatment plans with the goal of estimating the uncertainties of calculated organ doses. Photon beam phase-space files for TrueBeam linear accelerator were provided by Varian. These were used as incident sources in EGSnrc Monte Carlo simulations of radiation transport through the downstream jaws and MLC. Dynamic movements of the MLC leaves were fully modeled based on treatment plans using IMRT or VMAT techniques. The Monte Carlo calculated out-of-field doses were then compared with those calculated by Eclipse. The dose comparisons were performed for different beam energies and treatment sites, including head-and-neck, lung, and pelvis. For 6 MV (FF/FFF), 10 MV (FF/FFF), and 15 MV (FF) beams, Eclipse underestimated out-of-field local doses by 30%-50% compared with Monte Carlo calculations when the local dose was <1% of prescribed dose. The accuracy of out-of-field dose calculations using Eclipse is improved when collimator jaws were set at the smallest possible aperture for MLC openings. The Eclipse system consistently underestimates out-of-field dose by a factor of 2 for all beam energies studied at the local dose level of less than 1% of prescribed dose. These findings are useful in providing information on the uncertainties of out-of-field organ doses calculated by Eclipse treatment planning system.

Citing Articles

Evaluation of Dose Calculation Algorithms Accuracy for ISOgray Treatment Planning System in Motorized Wedged Treatment Fields.

Raghavi S, Sadoughi H, Ravari M, Behmadi M J Med Signals Sens. 2024; 14:31.

PMID: 39691405 PMC: 11651387. DOI: 10.4103/jmss.jmss_28_24.


Calculation of Organ Dose Distribution (in-field and Out-of-field) in Breast Cancer Radiotherapy on RANDO Phantom Using GEANT4 Application for Tomographic Emission (Gate) Monte Carlo Simulation.

Behmadi M, Toossi M, Nasseri S, Ravari M, Momennezhad M, Gholamhosseinian H J Med Signals Sens. 2024; 14:18.

PMID: 39100743 PMC: 11296572. DOI: 10.4103/jmss.jmss_25_23.


Comparison of 3DCRT and IMRT out-of-field doses in pediatric patients using Monte Carlo simulations with treatment planning system calculations and measurements.

Sa A, Barateiro A, Bednarz B, Almeida P, Vaz P, Madaleno T Front Oncol. 2022; 12:879167.

PMID: 35992845 PMC: 9388939. DOI: 10.3389/fonc.2022.879167.


Out-of-field doses from radiotherapy using photon beams: A comparative study for a pediatric renal treatment.

Colnot J, Zefkili S, Gschwind R, Huet C J Appl Clin Med Phys. 2021; 22(3):94-106.

PMID: 33547766 PMC: 7984471. DOI: 10.1002/acm2.13182.

References
1.
Kry S, Vassiliev O, Mohan R . Out-of-field photon dose following removal of the flattening filter from a medical accelerator. Phys Med Biol. 2010; 55(8):2155-66. DOI: 10.1088/0031-9155/55/8/003. View

2.
Van Den Heuvel F, Defraene G, Crijns W, Bogaerts R . Out-of-field contributions for IMRT and volumetric modulated arc therapy measured using gafchromic films and compared to calculations using a superposition/convolution based treatment planning system. Radiother Oncol. 2012; 105(1):127-32. DOI: 10.1016/j.radonc.2011.12.030. View

3.
Wang L, Ding G . The accuracy of the out-of-field dose calculations using a model based algorithm in a commercial treatment planning system. Phys Med Biol. 2014; 59(13):N113-28. DOI: 10.1088/0031-9155/59/13/N113. View

4.
Almberg S, Frengen J, Lindmo T . Monte Carlo study of in-field and out-of-field dose distributions from a linear accelerator operating with and without a flattening-filter. Med Phys. 2012; 39(8):5194-203. DOI: 10.1118/1.4738963. View

5.
Rogers D, Faddegon B, Ding G, Ma C, We J, Mackie T . BEAM: a Monte Carlo code to simulate radiotherapy treatment units. Med Phys. 1995; 22(5):503-24. DOI: 10.1118/1.597552. View