Objective: The purpose of this study was to investigate the degree of conversion (DC) and mechanical properties of a microhybrid Filtek Z250 (3M ESPE) resin composite after aging.

Method: The specimens were fabricated using circular molds to investigate Vickers microhardness (Vickers hardness number [VHN]) and DC, and were prepared according to ISO 4049 for flexural strength testing. The initial DC (%) of discs was recorded using attenuated total reflectance-Fourier transforming infrared spectroscopy. The initial VHN of the specimens was measured using a microhardness tester under a load of 300 g for 15 seconds and the flexural strength test was carried out with a universal testing machine (crosshead speed, 0.5 mm/min). The specimens were then subjected to thermocycling in 5°C and 55°C water baths. Properties were assessed after 1,000-10,000 cycles of thermocycling. The surfaces were evaluated using scanning electron microscopy (SEM). Data were analyzed using 1-way analysis of variance followed by the Tukey honest significant difference test.

Results: Statistical analysis showed that DC tended to increase up to 4,000 cycles, with no significant changes. VHN and flexural strength values significantly decreased upon thermal cycling when compared to baseline ( < 0.05). However, there was no significant difference between initial and post-thermocycling VHN results at 1,000 cycles. SEM images after aging showed deteriorative changes in the resin composite surfaces.

Conclusions: The Z250 microhybrid resin composite showed reduced surface microhardness and flexural strength and increased DC after thermocycling.

Citing Articles

Effect of food-simulating liquids and polishing times on the color stability of microhybrid and nanohybrid resin composites.

Fidan M, Cankaya N Discov Nano. 2025; 20(1):43.

PMID: 39979501 PMC: 11842679. DOI: 10.1186/s11671-025-04205-x.


Simulation of oral environmental conditions through artificial aging of teeth for the assessment of enamel discoloration in orthodontics.

Irgin C BMC Oral Health. 2024; 24(1):1533.

PMID: 39709403 PMC: 11662843. DOI: 10.1186/s12903-024-05353-9.


In Vitro Effects of Sof-Lex, Eve, and Astropol Polishing Systems on Composite Resin Surface Roughness after Aging.

Saati K, Valizadeh S, Rahmaniparast A, Karimi M Front Dent. 2024; 21:35.

PMID: 39588288 PMC: 11586639. DOI: 10.18502/fid.v21i35.16473.


Effect of CAD-CAM block thickness and translucency on the polymerization of luting materials.

Dogu Kaya B, Ozturk S, Senol A, Kahramanoglu E, Yilmaz Atali P, Tarcin B BMC Oral Health. 2024; 24(1):1384.

PMID: 39548438 PMC: 11566408. DOI: 10.1186/s12903-024-05171-z.


Comparative Strength Study of Indirect Permanent Restorations: 3D-Printed, Milled, and Conventional Dental Composites.

Tribst J, Veerman A, Pereira G, Kleverlaan C, Dal Piva A Clin Pract. 2024; 14(5):1940-1952.

PMID: 39311304 PMC: 11417927. DOI: 10.3390/clinpract14050154.


References
1.
Ferracane J, Berge H, Condon J . In vitro aging of dental composites in water--effect of degree of conversion, filler volume, and filler/matrix coupling. J Biomed Mater Res. 1998; 42(3):465-72. DOI: 10.1002/(sici)1097-4636(19981205)42:3<465::aid-jbm17>3.0.co;2-f. View

2.
Sideridou I, Achilias D . Elution study of unreacted Bis-GMA, TEGDMA, UDMA, and Bis-EMA from light-cured dental resins and resin composites using HPLC. J Biomed Mater Res B Appl Biomater. 2005; 74(1):617-26. DOI: 10.1002/jbm.b.30252. View

3.
Janda R, Roulet J, Latta M, Ruttermann S . The effects of thermocycling on the flexural strength and flexural modulus of modern resin-based filling materials. Dent Mater. 2006; 22(12):1103-8. DOI: 10.1016/j.dental.2005.09.005. View

4.
Tabatabaei M, Sadrai S, Bassir S, Veisy N, Dehghan S . Effect of food stimulated liquids and thermocycling on the monomer elution from a nanofilled composite. Open Dent J. 2013; 7:62-7. PMC: 3750967. DOI: 10.2174/1874210601307010062. View

5.
Toledano M, Osorio R, Osorio E, Fuentes V, Prati C, Garcia-Godoy F . Sorption and solubility of resin-based restorative dental materials. J Dent. 2003; 31(1):43-50. DOI: 10.1016/s0300-5712(02)00083-0. View