» Articles » PMID: 10071465

Thermal Cycling Procedures for Laboratory Testing of Dental Restorations

Overview
Journal J Dent
Publisher Elsevier
Specialty Dentistry
Date 1999 Mar 11
PMID 10071465
Citations 298
Authors
Affiliations
Soon will be listed here.
Abstract

Objectives: Exposure of restorations in extracted teeth to cyclic thermal fluctuations to simulate one of the many factors in the oral environment has been common in many tracer penetration, marginal gap and bond strength laboratory tests. Temperature changes used have rarely been substantiated with temperature measurements made in vivo and vary considerably between reports. Justification and standardization of regimen are required.

Data, Sources And Study Selection: An assessment of reports describing temperature changes of teeth in vivo is followed by an analysis of 130 studies of laboratory thermal cycling of teeth by 99 first authors selected from 25 journals. A clinically relevant thermal cycling regimen was derived from the in vivo information, and is suggested as a benchmark standard.

Conclusions: Variation of regimens used was large, making comparison of reports difficult. Reports of testing the effects of thermal cycling were often contradictory, but generally leakage increased with thermal stress, although it has never been demonstrated that cyclic testing is relevant to clinical failures. However, should this be done, the standard cyclic regimen defined is: 35 degrees C (28 s), 15 degrees C (2 s), 35 degrees C (28 s), 45 degrees C (2 s). No evidence of the number of cycles likely to be experienced in vivo was found and this requires investigation, but a provisional estimate of approximately 10,000 cycles per year is suggested. Thermal stressing of restoration interfaces is only of value when the initial bond is already known to be reliable. This is not the case for most current restorative materials.

Citing Articles

Effect of various solvents on the repairability of aged CAD/CAM provisional restorative materials with flowable resin composite: an in vitro study.

Chitpattanakul P, Prawatvatchara W, Limpuangthip N, Katheng A, Uasuwan P, Boonpitak K BMC Oral Health. 2025; 25(1):368.

PMID: 40069739 PMC: 11895317. DOI: 10.1186/s12903-025-05731-x.


Flexural Strength and Surface Properties of 3D-Printed Denture Base Resins-Effect of Build Angle, Layer Thickness and Aging.

Fouda S, Ji W, Gad M, AlGhamdi M, Rohr N Materials (Basel). 2025; 18(4).

PMID: 40004436 PMC: 11857092. DOI: 10.3390/ma18040913.


Bond strength of conventional resin-based adhesive cement and self-adhesive resin cement to CAD-CAM restorative materials.

Senol M, Gurbuz A, Oyar P BMC Oral Health. 2025; 25(1):296.

PMID: 39994593 PMC: 11853663. DOI: 10.1186/s12903-025-05527-z.


Translucency and color stability of advanced lithium disilicate ceramic material: An in vitro study.

Alazemi B, Rayyan M J Conserv Dent Endod. 2025; 28(1):33-38.

PMID: 39974677 PMC: 11835360. DOI: 10.4103/JCDE.JCDE_719_24.


Impact of polyethylene fiber-reinforced composite resin and thermomechanical cycling on dentin bond strength.

Pimentel M, Kantovitz K, Turssi C, Amaral F, Basting R, Martins L Braz Oral Res. 2025; 39:e13.

PMID: 39936712 PMC: 11808700. DOI: 10.1590/1807-3107bor-2025.vol39.013.