» Articles » PMID: 29754161

Motion-corrected Whole-heart PET-MR for the Simultaneous Visualisation of Coronary Artery Integrity and Myocardial Viability: an Initial Clinical Validation

Overview
Date 2018 May 14
PMID 29754161
Citations 12
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: Cardiac PET-MR has shown potential for the comprehensive assessment of coronary heart disease. However, image degradation due to physiological motion remains a challenge that could hinder the adoption of this technology in clinical practice. The purpose of this study was to validate a recently proposed respiratory motion-corrected PET-MR framework for the simultaneous visualisation of myocardial viability (F-FDG PET) and coronary artery anatomy (coronary MR angiography, CMRA) in patients with chronic total occlusion (CTO).

Methods: A cohort of 14 patients was scanned with the proposed PET-CMRA framework. PET and CMRA images were reconstructed with and without the proposed motion correction approach for comparison purposes. Metrics of image quality including visible vessel length and sharpness were obtained for CMRA for both the right and left anterior descending coronary arteries (RCA, LAD), and relative increase in F-FDG PET signal after motion correction for standard 17-segment polar maps was computed. Resulting coronary anatomy by CMRA and myocardial integrity by PET were visually compared against X-ray angiography and conventional Late Gadolinium Enhancement (LGE) MRI, respectively.

Results: Motion correction increased CMRA visible vessel length by 49.9% and 32.6% (RCA, LAD) and vessel sharpness by 12.3% and 18.9% (RCA, LAD) on average compared to uncorrected images. Coronary lumen delineation on motion-corrected CMRA images was in good agreement with X-ray angiography findings. For PET, motion correction resulted in an average 8% increase in F-FDG signal in the inferior and inferolateral segments of the myocardial wall. An improved delineation of myocardial viability defects and reduced noise in the F-FDG PET images was observed, improving correspondence to subendocardial LGE-MRI findings compared to uncorrected images.

Conclusion: The feasibility of the PET-CMRA framework for simultaneous cardiac PET-MR imaging in a short and predictable scan time (~11 min) has been demonstrated in 14 patients with CTO. Motion correction increased visible length and sharpness of the coronary arteries by CMRA, and improved delineation of the myocardium by F-FDG PET, resulting in good agreement with X-ray angiography and LGE-MRI.

Citing Articles

Extended MRI-based PET motion correction for cardiac PET/MRI.

Aizaz M, van der Pol J, Schneider A, Munoz C, Holtackers R, van Cauteren Y EJNMMI Phys. 2024; 11(1):36.

PMID: 38581561 PMC: 10998820. DOI: 10.1186/s40658-024-00637-z.


PET/MR imaging of inflammation in atherosclerosis.

Senders M, Calcagno C, Tawakol A, Nahrendorf M, Mulder W, Fayad Z Nat Biomed Eng. 2022; 7(3):202-220.

PMID: 36522465 DOI: 10.1038/s41551-022-00970-7.


Anatomical validation of automatic respiratory motion correction for coronary 18F-sodium fluoride positron emission tomography by expert measurements from four-dimensional computed tomography.

Lassen M, Tzolos E, Pan T, Kwiecinski J, Cadet S, Dey D Med Phys. 2022; 49(11):7085-7094.

PMID: 35766454 PMC: 9742185. DOI: 10.1002/mp.15834.


Low-Dose PET Imaging of Tumors in Lung and Liver Regions Using Internal Motion Estimation.

Woo S, Kim B, Ryu E, Ko I, Lee Y Diagnostics (Basel). 2021; 11(11).

PMID: 34829485 PMC: 8625002. DOI: 10.3390/diagnostics11112138.


Synergistic motion compensation strategies for positron emission tomography when acquired simultaneously with magnetic resonance imaging.

Polycarpou I, Soultanidis G, Tsoumpas C Philos Trans A Math Phys Eng Sci. 2021; 379(2204):20200207.

PMID: 34218675 PMC: 8255946. DOI: 10.1098/rsta.2020.0207.


References
1.
Rauscher I, Eiber M, Furst S, Souvatzoglou M, Nekolla S, Ziegler S . PET/MR imaging in the detection and characterization of pulmonary lesions: technical and diagnostic evaluation in comparison to PET/CT. J Nucl Med. 2014; 55(5):724-9. DOI: 10.2967/jnumed.113.129247. View

2.
Rischpler C, Langwieser N, Souvatzoglou M, Batrice A, van Marwick S, Snajberk J . PET/MRI early after myocardial infarction: evaluation of viability with late gadolinium enhancement transmurality vs. 18F-FDG uptake. Eur Heart J Cardiovasc Imaging. 2015; 16(6):661-9. DOI: 10.1093/ehjci/jeu317. View

3.
Etienne A, Botnar R, Van Muiswinkel A, Boesiger P, Manning W, Stuber M . "Soap-Bubble" visualization and quantitative analysis of 3D coronary magnetic resonance angiograms. Magn Reson Med. 2002; 48(4):658-66. DOI: 10.1002/mrm.10253. View

4.
Botnar R, Stuber M, Danias P, Kissinger K, Manning W . Improved coronary artery definition with T2-weighted, free-breathing, three-dimensional coronary MRA. Circulation. 1999; 99(24):3139-48. DOI: 10.1161/01.cir.99.24.3139. View

5.
Lau J, Laforest R, Sotoudeh H, Nie X, Sharma S, McConathy J . Evaluation of attenuation correction in cardiac PET using PET/MR. J Nucl Cardiol. 2015; 24(3):839-846. PMC: 6360086. DOI: 10.1007/s12350-015-0197-1. View