» Articles » PMID: 29719553

47 Consecutive Cases of Pipeline Flex Flow Diversion Utilizing a Novel Large-Bore Intracranial Intermediate Catheter: Nuances and Institutional Experience with the Syphontrak

Overview
Journal Interv Neurol
Date 2018 May 3
PMID 29719553
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

Background: The increasing complexity of modern neurointerventions has necessitated a shift in intracranial access techniques towards more robust distal support platforms. Here we present our experience with the Syphontrak Support Catheter (Codman Neuro, Raynham, MA, USA) in the triaxial platform for the implantation of the second-generation Pipeline Flex embolization device (PED Flex; Medtronic Neurovascular, Irvine, CA, USA).

Methods: We retrospectively identified patients who underwent PED Flex treatment utilizing the Syphontrak at a single institution. The procedural data collected included parent artery tortuosity, patient demographics, aneurysm characteristics, other equipment utilized, and catheter-related complications.

Results: A total of 47 consecutive aneurysm flow diversions were successfully performed using the Syphontrak. The patients' age ranged from 25 to 80 years (mean 57.3 ± 11.6) and 85% were women. The average aneurysm size was 4.8 ± 2.7 mm (range 2-14). All cases were in the anterior circulation, with 6 (12%) aneurysms located beyond the internal carotid artery termination. Significant cervical carotid tortuosity was present in 23% (11/47) of the cases and moderate-to-severe cavernous tortuosity (cavernous grade ≥2) in 51% (24/47) of the cases. The mean fluoroscopy time was 36.6 ± 14.8 min. In 12/47 cases (26%), vasospasm prophylaxis with intra-arterial verapamil infusion was performed. The Syphontrak was tracked to the intended distal position in all cases, with a 100% technical success of PED Flex implantation. Forty-six (98%) of the 47 patients were discharged home after an average length of stay of 1.38 days. No iatrogenic catheter-related vessel injury occurred. Transient, minor neurological morbidity occurred in 3 cases (6%) and 1 patient had a minor ischemic event (NIHSS score < 4) in the periprocedural period.

Conclusion: The Syphontrak is a new large-bore, multi-durometer intermediate catheter (IC) designed for use in modern neurointerventional procedures. We have shown its utility in 47 successful cases of PED Flex flow diversion of a wide range of complexity. The IC provides robust and atraumatic distal intracranial access while also providing an enhanced image quality with its large 0.060″ inner diameter.

Citing Articles

Use of a large-bore 088 intracranial access support catheter for delivery of large intracranial devices: case series with the TracStar LDP in 125 cases.

Campos J, Zarrin D, Meyer B, Khan M, Laghari F, Collard de Beaufort J J Neurointerv Surg. 2024; 16(12):1228-1231.

PMID: 38418227 PMC: 11671879. DOI: 10.1136/jnis-2023-021054.


Early institutional experience using the TracStar Large Distal Platform in endovascular flow diversion.

Bageac D, Gershon B, Shigematsu T, Majidi S, De Leacy R Neuroradiol J. 2021; 35(3):313-318.

PMID: 34473002 PMC: 9244741. DOI: 10.1177/19714009211041520.


Utilization of the Ballast Long Guiding Sheath for Neuroendovascular Procedures: Institutional Experience in 68 Cases.

Hassan A, Burke E, Monayao M, Tekle W Front Neurol. 2021; 12:578446.

PMID: 34025546 PMC: 8137819. DOI: 10.3389/fneur.2021.578446.


A Technical Report on the Performance of a New Large Bore Cerebral Aspiration Catheter, the First Results.

Benali F, Goldhoorn R, Wagemans B, van der Leij C, Brans R, de Boer S Cardiovasc Intervent Radiol. 2019; 42(12):1795-1799.

PMID: 31267150 PMC: 6823290. DOI: 10.1007/s00270-019-02280-z.


Flow-Diversion Treatment of Unruptured Saccular Anterior Communicating Artery Aneurysms: A Systematic Review and Meta-Analysis.

Cagnazzo F, Limbucci N, Nappini S, Renieri L, Rosi A, Laiso A AJNR Am J Neuroradiol. 2019; 40(3):497-502.

PMID: 30765379 PMC: 7028645. DOI: 10.3174/ajnr.A5967.

References
1.
Jiang B, Paff M, Colby G, Coon A, Lin L . Cerebral aneurysm treatment: modern neurovascular techniques. Stroke Vasc Neurol. 2017; 1(3):93-100. PMC: 5435202. DOI: 10.1136/svn-2016-000027. View

2.
Lin L, Colby G, Bender M, Xu R, Huang J, Tamargo R . Use of the 0.027-inch VIA microcatheter for delivery of Pipeline Flex: a technical note. J Neurointerv Surg. 2017; 9(7):689-693. DOI: 10.1136/neurintsurg-2016-012971. View

3.
Chaudhary N, Pandey A, Thompson B, Gandhi D, Ansari S, Gemmete J . Utilization of the Neuron 6 French 0.053 inch inner luminal diameter guide catheter for treatment of cerebral vascular pathology: continued experience with ultra distal access into the cerebral vasculature. J Neurointerv Surg. 2011; 4(4):301-6. DOI: 10.1136/neurintsurg-2011-010041. View

4.
Lin L, Bender M, Colby G, Beaty N, Jiang B, Campos J . Use of a next-generation multi-durometer long guide sheath for triaxial access in flow diversion: experience in 95 consecutive cases. J Neurointerv Surg. 2017; 10(2):137-142. DOI: 10.1136/neurintsurg-2017-013184. View

5.
Colby G, Lin L, Huang J, Tamargo R, Coon A . Utilization of the Navien distal intracranial catheter in 78 cases of anterior circulation aneurysm treatment with the Pipeline embolization device. J Neurointerv Surg. 2013; 5 Suppl 3:iii16-21. DOI: 10.1136/neurintsurg-2013-010692. View