» Articles » PMID: 29455762

BVS, RDN, IABP: The Afghanistan of Interventional Cardiology Trials

Overview
Journal Indian Heart J
Publisher Elsevier
Date 2018 Feb 20
PMID 29455762
Citations 2
Authors
Affiliations
Soon will be listed here.
Abstract

In the field of medicine and cardiology newer therapy and devices have been launched with a huge promise and a lot of hype. Unfortunately, over the course of time, a good many of them like biovascular scaffold, renal denervation and intra-aortic balloon pump have failed to live up to their initial promise so much so that some of them have been withdrawn. The reason for this downfall may be multifold from incomplete understanding of the patho-physiology of disease, incomplete understanding of mechanism of action of the therapy, in-appropriate application in clinical practice, in-efficient therapy development related to flawed trial design, regulatory impediments placed on the trials or deficits in application of scientific techniques. Here-in we investigate the specific reason for failure for some of these therapies and attempt to suggest a way forward.

Citing Articles

The Use of Cardioprotective Devices and Strategies in Patients Undergoing Percutaneous Procedures and Cardiac Surgery.

Abdul-Rahman T, Lizano-Jubert I, Garg N, Tejerina-Marion E, Bukhari S, Luisa Ek A Healthcare (Basel). 2023; 11(8).

PMID: 37107928 PMC: 10137626. DOI: 10.3390/healthcare11081094.


Response to the editorial titled "BVS, RDN, IABP: The Afghanistan of interventional clinical trials.

Panda P, Sharma A, Sharma Y Indian Heart J. 2018; 70(3):461-462.

PMID: 29961473 PMC: 6034036. DOI: 10.1016/j.ihj.2018.04.008.

References
1.
London A, Kimmelman J . Why clinical translation cannot succeed without failure. Elife. 2015; 4:e12844. PMC: 4657068. DOI: 10.7554/eLife.12844. View

2.
Mishra S . A fresh look at bioresorbable scaffold technology: Intuition pumps. Indian Heart J. 2017; 69(1):107-111. PMC: 5319118. DOI: 10.1016/j.ihj.2017.01.006. View

3.
Mishra S . Do we need to change the medical curriculum: regarding the pain of others. Indian Heart J. 2015; 67(3):187-91. PMC: 4495594. DOI: 10.1016/j.ihj.2015.05.015. View

4.
Mishra S . Upscaling cardiac assist devices in decompensated heart failure: Choice of device and its timing. Indian Heart J. 2016; 68 Suppl 1:S1-4. PMC: 4824335. DOI: 10.1016/j.ihj.2015.12.012. View

5.
Mishra S, Chu W, Torguson R, Wolfram R, Deible R, Suddath W . Role of prophylactic intra-aortic balloon pump in high-risk patients undergoing percutaneous coronary intervention. Am J Cardiol. 2006; 98(5):608-12. DOI: 10.1016/j.amjcard.2006.03.036. View