An acoustical handheld hydration monitor (HM) for assessing the water balance of the human body was developed. Dehydration is a critical public health problem. Many elderly over age of 65 are particularly vulnerable as are infants and young children. Given that dehydration is both preventable and reversible, the need for an easy-to-perform method for the detection of water imbalance is of the utmost clinical importance. The HM is based on an experimental fact that ultrasound velocity in muscle is a linear function of water content and can be referenced to the hydration status of the body. Studies on the validity of HM for the assessment of whole-body hydration status were conducted in the Appalachian State University, USA, on healthy young adults and on elderly subjects residing at an assisted living facility. The HM was able to track changes in total body water during periods of acute dehydration and rehydration in athletes and day-to-day and diurnal variability of hydration in elderly. Results of human studies indicate that HM has a potential to become an efficient tool for detecting abnormal changes in the body hydration status.

Citing Articles

Non-invasive approaches to hydration assessment: a literature review.

Tahar A, Zrour H, Dupont S, Pozdzik A Urolithiasis. 2024; 52(1):132.

PMID: 39325254 DOI: 10.1007/s00240-024-01630-y.

References
1.
McConnochie K, Conners G, Lu E, Wilson C . How commonly are children hospitalized for dehydration eligible for care in alternative settings?. Arch Pediatr Adolesc Med. 1999; 153(12):1233-41. DOI: 10.1001/archpedi.153.12.1233. View

2.
Sarvazyan A, Tatarinov A, Sarvazyan N . Ultrasonic assessment of tissue hydration status. Ultrasonics. 2005; 43(8):661-71. DOI: 10.1016/j.ultras.2005.03.005. View

3.
Rosler A, Lehmann F, Krause T, Wirth R, von Renteln-Kruse W . Nutritional and hydration status in elderly subjects: clinical rating versus bioimpedance analysis. Arch Gerontol Geriatr. 2009; 50(3):e81-5. DOI: 10.1016/j.archger.2009.06.007. View

4.
Simon C, Vanbaren P, Ebbini E . Two-dimensional temperature estimation using diagnostic ultrasound. IEEE Trans Ultrason Ferroelectr Freq Control. 2008; 45(4):1088-99. DOI: 10.1109/58.710592. View

5.
Cheuvront S, Carter 3rd R, Sawka M . Fluid balance and endurance exercise performance. Curr Sports Med Rep. 2003; 2(4):202-8. DOI: 10.1249/00149619-200308000-00006. View