Two-dimensional Temperature Estimation Using Diagnostic Ultrasound

Overview
Date 2008 Feb 5
PMID 18244264
Citations 53
Authors
Affiliations
Soon will be listed here.
Abstract

A two-dimensional temperature estimation method was developed based on the detection of shifts in echo location of backscattered ultrasound from a region of tissue undergoing thermal therapy. The echo shifts are due to the combination of the local temperature dependence of speed of sound and thermal expansion in the heated region. A linear relationship between these shifts and the underlying tissue temperature rise is derived from first principles and experimentally validated. The echo shifts are estimated from the correlation of successive backscattered ultrasound frames, and the axial derivative of the accumulated echo shifts is shown to be proportional to the temperature rise. Sharp lateral gradients in the temperature distribution introduce ripple on the estimates of the echo shifts due to a thermo-acoustic lens effect. This ripple can be effectively reduced by filtering the echo shifts along the axial and lateral directions upon differentiation. However, this is achieved at the expense of spatial resolution. Experimental evaluation of the accuracy (0.5 degrees C) and spatial resolution (2 mm) of the algorithm in tissue mimicking phantoms was conducted using a diagnostic ultrasound imaging scanner and a therapeutic ultrasound unit. The estimated temperature maps were overlaid on the gray-scale ultrasound images to illustrate the applicability of this technique for image guidance of focused ultrasound thermal therapy.

Citing Articles

Therapeutic ultrasound transducer technology and monitoring techniques: a review with clinical examples.

Lafond M, Payne A, Lafon C Int J Hyperthermia. 2024; 41(1):2389288.

PMID: 39134055 PMC: 11375802. DOI: 10.1080/02656736.2024.2389288.


Techniques for Temperature Monitoring of Myocardial Tissue Undergoing Radiofrequency Ablation Treatments: An Overview.

Zaltieri M, Massaroni C, Cauti F, Schena E Sensors (Basel). 2021; 21(4).

PMID: 33669692 PMC: 7922285. DOI: 10.3390/s21041453.


Non-invasive Assessment of Liver Fat in ob/ob Mice Using Ultrasound-Induced Thermal Strain Imaging and Its Correlation with Hepatic Triglyceride Content.

Khalid W, Farhat N, Lavery L, Jarnagin J, DeLany J, Kim K Ultrasound Med Biol. 2021; 47(4):1067-1076.

PMID: 33468357 PMC: 7936391. DOI: 10.1016/j.ultrasmedbio.2020.12.014.


Imaging-based internal body temperature measurements: The journal .

Raiko J, Koskensalo K, Sainio T Temperature (Austin). 2020; 7(4):363-388.

PMID: 33251282 PMC: 7678923. DOI: 10.1080/23328940.2020.1769006.


Intraoperative Speckle Variance Optical Coherence Tomography for Tissue Temperature Monitoring During Cutaneous Laser Therapy.

Guo S, Wei S, Lee S, Sheu M, Kang S, Kang J IEEE J Transl Eng Health Med. 2020; 7:1800608.

PMID: 32309052 PMC: 6788854. DOI: 10.1109/JTEHM.2019.2943317.