» Articles » PMID: 29299315

A Novel Fibrinogen Mutation: G. 3057 C > T (p. Arg104 > Cys) Impairs Fibrinogen Secretion

Overview
Journal BMC Hematol
Publisher Biomed Central
Specialty Hematology
Date 2018 Jan 5
PMID 29299315
Citations 2
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Abnormal fibrinogens can be caused by clinically silent hereditary mutations. A new case was detected accidentally in an 11-year-old girl when routine pre-operative coagulation tests were performed for nasal turbinate surgery.

Methods: The fibrinogen genes FGA, FGG and FGB were sequenced using standard protocols. The kinetics of fibrin formation were followed by turbidity at 350 nm. Purified fibrinogen was incubated with plasmin, and the degradation products analyzed by SDS/PAGE. The formation of fibrinogen-albumin complexes was analyzed by immunobloting. Fibrin structure was examined in a Nikon Eclipse TE 2000-U laser microscope. Secretion of the variant protein was analyzed directly by reverse phase-electrospray time of flight-mass spectrometry (TOF-MS).

Results: DNA sequencing revealed a novel heterozygous g. 3057 C > T mutation in the that predicts a p. Arg104 > Cys substitution, in the proband and her father. Both patients were asymptomatic with low functional and antigen fibrinogen concentrations. The proband's plasma fibrinogen polymerization was almost normal, with a 12% decrease in the final turbidity, while, the father's fibrin formation had a diminished slope and final turbidity (2.5× and 40%, respectively). Aα Arg104 is located at a plasmin cleavage site in the coiled-coil region of fibrinogen. However, the father's fibrinogen plasmin degradation was normal. Although the exchanged Cys introduces an unpaired -SH, immunoblotting showed no fibrinogen-albumin complexes. Furthermore, the plasma clot structure observed by confocal microscopy appeared almost normal. TOF-MS showed that the variant Aα chain was underrepresented in plasma and made up only about 25% of the total.

Conclusions: The low expression of the Aα Arg104 > Cys chain in circulation could account for the observed hypodysfibrinogenemia.

Citing Articles

Predictive Value of the D-Dimer-to-Fibrinogen Ratio for Acute Kidney Injury after Living-Donor Liver Transplantation: A Retrospective Observational Cohort Study Using Logistic Regression and Propensity Score Matching Analyses.

Park J, Kim M, Kim J, Choi H, Hong S J Clin Med. 2024; 13(18).

PMID: 39336986 PMC: 11432109. DOI: 10.3390/jcm13185499.


Predictive utility of fibrinogen in acute kidney injury in living donor liver transplantation: A propensity score-matching analysis.

Park J, Joo M, Choi H, Hong S, Park C, Choi J PLoS One. 2021; 16(6):e0252715.

PMID: 34086798 PMC: 8177619. DOI: 10.1371/journal.pone.0252715.

References
1.
Doolittle R, Goldbaum D, Doolittle L . Designation of sequences involved in the "coiled-coil" interdomainal connections in fibrinogen: constructions of an atomic scale model. J Mol Biol. 1978; 120(2):311-25. DOI: 10.1016/0022-2836(78)90070-0. View

2.
Cunningham M, Brandt J, Laposata M, Olson J . Laboratory diagnosis of dysfibrinogenemia. Arch Pathol Lab Med. 2002; 126(4):499-505. DOI: 10.5858/2002-126-0499-LDOD. View

3.
Blomback B, Okada M . Fibrin gel structure and clotting time. Thromb Res. 1982; 25(1-2):51-70. DOI: 10.1016/0049-3848(82)90214-6. View

4.
INGRAM I . The determination of plasma fibrinogen by the clot-weight method. Biochem J. 1952; 51(5):583-5. PMC: 1197899. DOI: 10.1042/bj0510583. View

5.
Casini A, Brungs T, Lavenu-Bombled C, Vilar R, Neerman-Arbez M, de Moerloose P . Genetics, diagnosis and clinical features of congenital hypodysfibrinogenemia: a systematic literature review and report of a novel mutation. J Thromb Haemost. 2017; 15(5):876-888. DOI: 10.1111/jth.13655. View