» Articles » PMID: 29169880

Evaluating the Benefit of Elevated Acoustic Output in Harmonic Motion Estimation in Ultrasonic Shear Wave Elasticity Imaging

Overview
Specialty Radiology
Date 2017 Nov 25
PMID 29169880
Citations 9
Authors
Affiliations
Soon will be listed here.
Abstract

Harmonic imaging techniques have been applied in ultrasonic elasticity imaging to obtain higher-quality tissue motion tracking data. However, harmonic tracking can be signal-to-noise ratio and penetration depth limited during clinical imaging, resulting in decreased yield of successful shear wave speed measurements. A logical approach is to increase the source pressure, but the in situ pressures used in diagnostic ultrasound have been subject to a de facto upper limit based on the Food and Drug Administration guideline for the mechanical index (MI <1.9). A recent American Institute of Ultrasound in Medicine report concluded that an in situ MI up to 4.0 could be warranted without concern for increased risk of cavitation in non-fetal tissues without gas bodies if there were a concurrent clinical benefit. This work evaluates the impact of using an elevated MI in harmonic motion tracking for hepatic shear wave elasticity imaging. The studies indicate that high-MI harmonic tracking increased shear wave speed estimation yield by 27% at a focal depth of 5 cm, with larger yield increase in more difficult-to-image patients. High-MI tracking improved harmonic tracking data quality by increasing the signal-to-noise ratio and decreasing jitter in the tissue motion data. We conclude that there is clinical benefit to use of elevated acoustic output in shear wave tracking, particularly in difficult-to-image patients.

Citing Articles

The Future Is Beyond Bright: The Evolving Role of Quantitative US for Fatty Liver Disease.

Ozturk A, Kumar V, Pierce T, Li Q, Baikpour M, Rosado-Mendez I Radiology. 2023; 309(2):e223146.

PMID: 37934095 PMC: 10695672. DOI: 10.1148/radiol.223146.


Quantifying the Impact of Imaging Through Body Walls on Shear Wave Elasticity Measurements.

Zhang B, Bottenus N, Jin F, Nightingale K Ultrasound Med Biol. 2022; 49(3):734-749.

PMID: 36564217 PMC: 9908830. DOI: 10.1016/j.ultrasmedbio.2022.10.005.


Liver fibrosis assessment: MR and US elastography.

Ozturk A, Olson M, Samir A, Venkatesh S Abdom Radiol (NY). 2021; 47(9):3037-3050.

PMID: 34687329 PMC: 9033887. DOI: 10.1007/s00261-021-03269-4.


On the Relationship between Spatial Coherence and In Situ Pressure for Abdominal Imaging.

Zhang B, Pinton G, Nightingale K Ultrasound Med Biol. 2021; 47(8):2310-2320.

PMID: 33985826 PMC: 8494065. DOI: 10.1016/j.ultrasmedbio.2021.03.008.


Quantifying the Effect of Abdominal Body Wall on In Situ Peak Rarefaction Pressure During Diagnostic Ultrasound Imaging.

Zhang B, Pinton G, Deng Y, Nightingale K Ultrasound Med Biol. 2021; 47(6):1548-1558.

PMID: 33722439 PMC: 8494063. DOI: 10.1016/j.ultrasmedbio.2021.01.028.


References
1.
Palmeri M, Wang M, Rouze N, Abdelmalek M, Guy C, Moser B . Noninvasive evaluation of hepatic fibrosis using acoustic radiation force-based shear stiffness in patients with nonalcoholic fatty liver disease. J Hepatol. 2011; 55(3):666-672. PMC: 3092839. DOI: 10.1016/j.jhep.2010.12.019. View

2.
Ferraioli G, Filice C, Castera L, Choi B, Sporea I, Wilson S . WFUMB guidelines and recommendations for clinical use of ultrasound elastography: Part 3: liver. Ultrasound Med Biol. 2015; 41(5):1161-79. DOI: 10.1016/j.ultrasmedbio.2015.03.007. View

3.
Nightingale K, Church C, Harris G, Wear K, Bailey M, Carson P . Conditionally Increased Acoustic Pressures in Nonfetal Diagnostic Ultrasound Examinations Without Contrast Agents: A Preliminary Assessment. J Ultrasound Med. 2015; 34(7):1-41. PMC: 4822701. DOI: 10.7863/ultra.34.7.15.13.0001. View

4.
Deng Y, Palmeri M, Rouze N, Rosenzweig S, Abdelmalek M, Nightingale K . Analyzing the Impact of Increasing Mechanical Index and Energy Deposition on Shear Wave Speed Reconstruction in Human Liver. Ultrasound Med Biol. 2015; 41(7):1948-57. PMC: 4461469. DOI: 10.1016/j.ultrasmedbio.2015.02.019. View

5.
Thomas J, Rubin D . Tissue harmonic imaging: why does it work?. J Am Soc Echocardiogr. 1998; 11(8):803-8. DOI: 10.1016/s0894-7317(98)70055-0. View