Improvement of Shear Wave Motion Detection Using Harmonic Imaging in Healthy Human Liver

Overview
Specialty Radiology
Date 2016 Jan 25
PMID 26803391
Citations 8
Authors
Affiliations
Soon will be listed here.
Abstract

Quantification of liver elasticity is a major application of shear wave elasticity imaging (SWEI) to non-invasive assessment of liver fibrosis stages. SWEI measurements can be highly affected by ultrasound image quality. Ultrasound harmonic imaging has exhibited a significant improvement in ultrasound image quality as well as for SWEI measurements. This was previously illustrated in cardiac SWEI. The purpose of this study was to evaluate liver shear wave particle displacement detection and shear wave velocity (SWV) measurements with fundamental and filter-based harmonic ultrasound imaging. In a cohort of 17 patients with no history of liver disease, a 2.9-fold increase in maximum shear wave displacement, a 0.11 m/s decrease in the overall interquartile range and median SWV and a 17.6% increase in the success rate of SWV measurements were obtained when filter-based harmonic imaging was used instead of fundamental imaging.

Citing Articles

Twin Peak Method for Estimating Tissue Viscoelasticity using Shear Wave Elastography.

Adikary S, Urban M, Guddati M ArXiv. 2024; .

PMID: 39606734 PMC: 11601804.


Evaluation of Robustness of Local Phase Velocity Imaging in Homogenous Tissue-Mimicking Phantoms.

Wood B, Kijanka P, Liu H, Urban M Ultrasound Med Biol. 2021; 47(12):3514-3528.

PMID: 34456084 PMC: 8578323. DOI: 10.1016/j.ultrasmedbio.2021.08.002.


On the Relationship between Spatial Coherence and In Situ Pressure for Abdominal Imaging.

Zhang B, Pinton G, Nightingale K Ultrasound Med Biol. 2021; 47(8):2310-2320.

PMID: 33985826 PMC: 8494065. DOI: 10.1016/j.ultrasmedbio.2021.03.008.


Local Phase Velocity Based Imaging of Viscoelastic Phantoms and Tissues.

Kijanka P, Urban M IEEE Trans Ultrason Ferroelectr Freq Control. 2020; 68(3):389-405.

PMID: 31976887 PMC: 7590236. DOI: 10.1109/TUFFC.2020.2968147.


Distributing Synthetic Focusing Over Multiple Push-Detect Events Enhances Shear Wave Elasticity Imaging Performance.

Ahmed R, Doyley M IEEE Trans Ultrason Ferroelectr Freq Control. 2019; 66(7):1170-1184.

PMID: 30990427 PMC: 6701192. DOI: 10.1109/TUFFC.2019.2911036.


References
1.
Kremkau F, Taylor K . Artifacts in ultrasound imaging. J Ultrasound Med. 1986; 5(4):227-37. DOI: 10.7863/jum.1986.5.4.227. View

2.
Nierhoff J, Chavez Ortiz A, Herrmann E, Zeuzem S, Friedrich-Rust M . The efficiency of acoustic radiation force impulse imaging for the staging of liver fibrosis: a meta-analysis. Eur Radiol. 2013; 23(11):3040-53. DOI: 10.1007/s00330-013-2927-6. View

3.
Song P, Urban M, Manduca A, Greenleaf J, Chen S . Coded excitation plane wave imaging for shear wave motion detection. IEEE Trans Ultrason Ferroelectr Freq Control. 2015; 62(7):1356-72. PMC: 4530976. DOI: 10.1109/TUFFC.2015.007062. View

4.
Ferraioli G, Filice C, Castera L, Choi B, Sporea I, Wilson S . WFUMB guidelines and recommendations for clinical use of ultrasound elastography: Part 3: liver. Ultrasound Med Biol. 2015; 41(5):1161-79. DOI: 10.1016/j.ultrasmedbio.2015.03.007. View

5.
Fierbinteanu-Braticevici C, Andronescu D, Usvat R, Cretoiu D, Baicus C, Marinoschi G . Acoustic radiation force imaging sonoelastography for noninvasive staging of liver fibrosis. World J Gastroenterol. 2009; 15(44):5525-32. PMC: 2785054. DOI: 10.3748/wjg.15.5525. View