» Articles » PMID: 29116237

Advantages of a Technique Using Two 50 Degree Arcs in Simultaneous Integrated Boost Radiotherapy for Left-sidebreast Cancer

Overview
Journal Sci Rep
Specialty Science
Date 2017 Nov 9
PMID 29116237
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

This study evaluated radiotherapy techniques with 15 cases for simultaneous integrated boost to treat whole left breast and tumor bed following breast conserving surgery. Treatment plans were generated using three techniques: volumetric modulated arc therapy (VMAT) with a partial arc of 190° (1ARC), VMAT with two tangential mini-arcs of 50° each (2TARC) and intensity modulated radiation therapy with four fixed angle fields (4IMRT). Dosimetric parameters for the whole breast (Target), the boost tumor bed (Boost), and surrounding normal organs were compared. Chair Index (CHI) was introduced to evaluate the dose homogeneity in Target given the two levels of prescription dose. The dose coverage in Target was better in 1ARC and 2TARC than that in 4IMRT. The mean CHI in 1ARC (2.47) and 2TARC (2.62) were higher than that in 4IMRT (1.71, p < 0.05), and this indicated the dose homogeneity of Target was better in 1ARC and 2TARC than that in 4IMRT. The mean doses to right lung, and contralateral breast in 4IMRT were lower than those in 2TARC but the differences between them were small. 2TARC was better than 4IMRT with respect to the dose to ipsilateral lung and heart. Overall, 2TARC was optimal among three techniques.

Citing Articles

Dose and organ displacement comparisons with breast conservative radiotherapy using abdominal and thoracic deep-inspiration breath-holds: A comparative dosimetric study.

Matsumoto Y, Kunieda E, Futakami N, Akiba T, Nagao R, Fukuzawa T J Appl Clin Med Phys. 2023; 24(4):e13888.

PMID: 36617188 PMC: 10113706. DOI: 10.1002/acm2.13888.


Knowledge-based DVH estimation and optimization for breast VMAT plans with and without avoidance sectors.

Fogliata A, Parabicoli S, Paganini L, Reggiori G, Lobefalo F, Cozzi L Radiat Oncol. 2022; 17(1):200.

PMID: 36474297 PMC: 9724419. DOI: 10.1186/s13014-022-02172-6.


Examination of the dose distribution of volumetric modulated arc radiotherapy using a high-definition multi-leaf collimator for breast cancer patients with irradiated regional lymph nodes.

Matsumoto Y, Kunieda E, Futakami N, Akiba T, Nagao R, Fukuzawa T Rep Pract Oncol Radiother. 2022; 27(4):634-643.

PMID: 36196412 PMC: 9521697. DOI: 10.5603/RPOR.a2022.0081.


New fractionations in breast cancer: a dosimetric study of 3D-CRT versus VMAT.

Piras A, Menna S, DAviero A, Marazzi F, Mazzini A, Cusumano D J Med Radiat Sci. 2021; 69(2):227-235.

PMID: 34551211 PMC: 9163458. DOI: 10.1002/jmrs.530.


Evaluation of abches and volumetric modulated arc therapy under deep inspiration breath-hold technique for patients with left-sided breast cancer: A retrospective observational study.

Yeh T, Chi M, Chi K, Hsu C Medicine (Baltimore). 2019; 98(39):e17340.

PMID: 31574873 PMC: 6775396. DOI: 10.1097/MD.0000000000017340.

References
1.
Fogliata A, Seppala J, Reggiori G, Lobefalo F, Palumbo V, De Rose F . Dosimetric trade-offs in breast treatment with VMAT technique. Br J Radiol. 2016; 90(1070):20160701. PMC: 5685098. DOI: 10.1259/bjr.20160701. View

2.
Zhao H, He M, Cheng G, Han D, Wu N, Shi D . A comparative dosimetric study of left sided breast cancer after breast-conserving surgery treated with VMAT and IMRT. Radiat Oncol. 2015; 10:231. PMC: 4650319. DOI: 10.1186/s13014-015-0531-4. View

3.
Liu H, Chen X, He Z, Li J . Evaluation of 3D-CRT, IMRT and VMAT radiotherapy plans for left breast cancer based on clinical dosimetric study. Comput Med Imaging Graph. 2016; 54:1-5. DOI: 10.1016/j.compmedimag.2016.10.001. View

4.
Fippel M . Fast Monte Carlo dose calculation for photon beams based on the VMC electron algorithm. Med Phys. 1999; 26(8):1466-75. DOI: 10.1118/1.598676. View

5.
Badakhshi H, Kaul D, Nadobny J, Wille B, Sehouli J, Budach V . Image-guided volumetric modulated arc therapy for breast cancer: a feasibility study and plan comparison with three-dimensional conformal and intensity-modulated radiotherapy. Br J Radiol. 2013; 86(1032):20130515. PMC: 3856548. DOI: 10.1259/bjr.20130515. View