» Articles » PMID: 29092377

μOCT Imaging Using Depth of Focus Extension by Self-imaging Wavefront Division in a Common-path Fiber Optic Probe

Overview
Journal Opt Express
Date 2017 Nov 3
PMID 29092377
Citations 18
Authors
Affiliations
Soon will be listed here.
Abstract

Optical coherence tomography (OCT) is an attractive medical modality due to its ability to acquire high-resolution, cross-sectional images inside the body using flexible, small-diameter, scanning fiber optic probes. Conventional, cross-sectional OCT imaging technologies have approximately 10-μm axial resolution and 30-μm lateral resolution, specifications that enable the visualization of microscopic architectural morphology. While this resolution is useful for many clinical applications, it is insufficient for resolving individual cells that characterize many diseases. To address this gap, a supercontinuum-laser-based, μm-resolution OCT (μOCT) system and a 500 μm-diameter, extended depth of focus single fiber optic probe for endoscopic and intravascular imaging were designed and fabricated. At the distal tip of the fiber optic probe, a cylindrical waveguide was used to divide the wavefront to provide multiple circular propagation modes. Once transmitted through a relatively high NA lens (NA >0.1), these modes were projected as multiple coaxial foci (~3 μm full width at half maximum (FWHM)) over a greatly extended focal depth range. The distal tip of the probe also contained a common-path reference reflectance to minimize polarization and dispersion imbalances between sample and reference arm light. Measurements showed that the probe provides a 20-fold depth of focus extension, maintaining a 3-5 µm lateral resolution (FWHM of PSF) and a 2 μm axial resolution over a depth range of approximately 1 mm. These results suggest that this new optical configuration will be useful for achieving high-resolution, cross-sectional OCT imaging in catheter/endoscope-based medical imaging devices.

Citing Articles

Dynamic micro-optical coherence tomography enables structural and metabolic imaging of the mammalian cochlea.

Schulz-Hildebrandt H, Spasic S, Hou F, Ting K, Batts S, Tearney G Front Mol Neurosci. 2024; 17:1436837.

PMID: 39449964 PMC: 11499234. DOI: 10.3389/fnmol.2024.1436837.


High-speed forward-viewing optical coherence tomography probe based on Lissajous sampling and sparse reconstruction.

Wu X, Ishrak R, Reihanisaransari R, Verma Y, Spring B, Singh K Opt Lett. 2024; 49(13):3652-3655.

PMID: 38950232 PMC: 11515085. DOI: 10.1364/OL.521595.


Ultra-thin light-weight laser-induced-graphene (LIG) diffractive optics.

Lee Y, Low M, Yang D, Nam H, Le T, Lee S Light Sci Appl. 2023; 12(1):146.

PMID: 37322023 PMC: 10272213. DOI: 10.1038/s41377-023-01143-0.


Line-field confocal optical coherence tomography for three-dimensional skin imaging.

Ogien J, Daures A, Cazalas M, Perrot J, Dubois A Front Optoelectron. 2023; 13(4):381-392.

PMID: 36641566 PMC: 9743950. DOI: 10.1007/s12200-020-1096-x.


Extended depth of focus by self-imaging wavefront division with the mirror tunnel.

Sheil C, Wartak A, Spicer G, Tearney G J Opt Soc Am A Opt Image Sci Vis. 2022; 39(4):711-725.

PMID: 35471398 PMC: 9232290. DOI: 10.1364/JOSAA.448848.


References
1.
Zhu X, Schulzgen A, Wei H, Kieu K, Peyghambarian N . White light Bessel-like beams generated by miniature all-fiber device. Opt Express. 2011; 19(12):11365-74. DOI: 10.1364/OE.19.011365. View

2.
Ralston T, Marks D, Carney P, Boppart S . Interferometric synthetic aperture microscopy. Nat Phys. 2015; 3(2):129-134. PMC: 4308056. DOI: 10.1038/nphys514. View

3.
Allison S, Gillies G . Observations of and applications for self-imaging in optical fibers. Appl Opt. 2010; 33(10):1802-5. DOI: 10.1364/AO.33.001802. View

4.
Standish B, Lee K, Mariampillai A, Munce N, Leung M, Yang V . In vivo endoscopic multi-beam optical coherence tomography. Phys Med Biol. 2010; 55(3):615-22. DOI: 10.1088/0031-9155/55/3/004. View

5.
Leitgeb R, Villiger M, Bachmann A, Steinmann L, Lasser T . Extended focus depth for Fourier domain optical coherence microscopy. Opt Lett. 2006; 31(16):2450-2. DOI: 10.1364/ol.31.002450. View