» Articles » PMID: 29087000

Pulmonary Vein Isolation with Real-time Pulmonary Vein Potential Recording Using Second-generation Cryoballoon: Procedural and Biophysical Predictors of Acute Pulmonary Vein Reconnection

Overview
Date 2017 Nov 1
PMID 29087000
Citations 9
Authors
Affiliations
Soon will be listed here.
Abstract

Objective: The study sought to evaluate the procedural and biophysical factors related to acute pulmonary vein isolation (PVI) guided by real-time pulmonary vein (PV) potential recordings.

Methods: A total of 180 consecutive patients with drug-resistant atrial fibrillation (AF) undergoing CB2 (second-generation version of cryoballoon) ablation were enrolled. Real-time monitoring of PV potentials was obtained using an inner lumen spiral mapping catheter.

Results: Acute isolation was achieved in all PVs without touch-up ablation. Real-time assessment of PV disconnection was possible in 611 of 711 (85.9%) PVs. A total of 617 (86.8%) PVs were isolated during the initial freeze. Longer time cycle integration (TCI) (TTI * freeze cycle, TCI) (254.6 ± 112.8 seconds vs 74.1 ± 59.7 seconds, P < 0.001), time to isolation (TTI) (94.3 ± 34.0 seconds vs 46.3 ± 26.2 seconds, P < 0.001), higher nadir temperature (-45.5 ± 5.3°C vs -50.4 ± 5.5°C, P < 0.001), longer time to -40°C (77.3 ± 22.7 seconds vs 55.7 ± 23.2 seconds, P < 0.001), faster interval rewarming time at 0°C (9.4 ± 4.3 seconds vs 12.4 ± 4.9 seconds, P = 0.008), and total balloon rewarming time (38.1 ± 11.6 seconds vs 47.7 ± 14.0 seconds, P = 0.003) were observed in PVs with acute reconduction. TTI ≤ 65 seconds predicted absence of acute reconnection with 84.2% sensitivity and 75.7% specificity, whereas TCI ≤ 119 seconds presented 94.7% sensitivity and 80.2% specificity. At a mean follow-up of 4.7 ± 1.4 months, 82.2% of patients were free of AF. None of those with PV reconnections suffered from AF recurrences.

Conclusions: The ablation using CB2 is effective in achieving acute PVI. Real-time assessment of PVI could be achieved during CB application in 86% of PVs. The incidence of spontaneous PV reconnection is very low, observed in just 3% of isolated PVs. TTI ≤ 65 seconds and TCI ≤ 119 seconds predicted absence of acute PV reconnection. Although they may identify effective cryoapplications in the acute phase, their performance still needs to be verified in the long term.

Citing Articles

Stay frosty - Improving outcomes from cryoballoon pulmonary vein isolation.

Denham N, Nair K Indian Pacing Electrophysiol J. 2023; 23(5):149-150.

PMID: 37652620 PMC: 10491957. DOI: 10.1016/j.ipej.2023.08.003.


Comparison of Using Second-Generation Cryoballoon and Radiofrequency Catheter for Atrial Fibrillation Ablation in Patients With the Common Ostium of Inferior Pulmonary Veins.

Li J, Xie H, Sun Q, Guo X, Chen Y, Cao Z Front Cardiovasc Med. 2022; 8:794834.

PMID: 35087882 PMC: 8787139. DOI: 10.3389/fcvm.2021.794834.


Safety and Efficacy Using the Second-Generation Cryoballoon in Patients With Atrial Fibrillation and a Common Ostium of Inferior Pulmonary Veins.

Xie H, Guo X, Yang J, Li J, Chen Y, Cao Z Front Cardiovasc Med. 2021; 8:683315.

PMID: 34557527 PMC: 8452976. DOI: 10.3389/fcvm.2021.683315.


Predicting early reconnection after cryoballoon ablation with procedural and biophysical parameters.

Kece F, de Riva M, Alizadeh Dehnavi R, Wijnmaalen A, Mertens B, Schalij M Heart Rhythm O2. 2021; 2(3):290-297.

PMID: 34337580 PMC: 8322820. DOI: 10.1016/j.hroo.2021.03.007.


A novel individualized strategy for cryoballoon catheter ablation in patients with paroxysmal atrial fibrillation.

Ding J, Xu J, Ma W, Chen B, Yang P, Qi Y BMC Cardiovasc Disord. 2019; 19(1):299.

PMID: 31847803 PMC: 6918665. DOI: 10.1186/s12872-019-01295-1.