Abstract

Lissajous microscanners are very attractive in compact laser scanning applications such as endomicroscopy or pro-projection display owing to high mechanical stability and low operating voltages. The scanning frequency serves as a critical factor for determining the scanning imaging quality. Here we report the selection rule of scanning frequencies that can realize high definition and high frame-rate (HDHF) full-repeated Lissajous scanning imaging. The fill factor (FF) monotonically increases with the total lobe number of a Lissajous curve, i.e., the sum of scanning frequencies divided by the great common divisor (GCD) of bi-axial scanning frequencies. The frames per second (FPS), called the pattern repeated rate or the frame rate, linearly increases with GCD. HDHF Lissajous scanning is achieved at the bi-axial scanning frequencies, where the GCD has the maximum value among various sets of the scanning frequencies satisfying the total lobe number for a target FF. Based on this selection rule, the experimental results clearly demonstrate that conventional Lissajous scanners substantially increase both FF and FPS by slightly modulating the scanning frequencies at near the resonance within the resonance bandwidth of a Lissajous scanner. This selection rule provides a new guideline for HDHF Lissajous scanning in compact laser scanning systems.

Citing Articles

CRASH2p: Closed-loop Two Photon Imaging in a Freely Moving Animal.

McNulty P, Wu R, Yamaguchi A, Heckscher E, Haas A, Nwankpa A bioRxiv. 2024; .

PMID: 38826435 PMC: 11142166. DOI: 10.1101/2024.05.22.595209.


A prospective multicenter assessor blinded pilot study using confocal laser endomicroscopy for intraoperative brain tumor diagnosis.

Byun Y, Won J, Hong D, Kang H, Kim J, Yu M Sci Rep. 2024; 14(1):6784.

PMID: 38514670 PMC: 10957981. DOI: 10.1038/s41598-024-52494-6.


Real-time Histological Evaluation of Gastric Cancer Tissue by Using a Confocal Laser Endomicroscopic System.

Bae H, Cho H, Jo Y, Heo S, Chu J, Choi S In Vivo. 2024; 38(2):855-863.

PMID: 38418139 PMC: 10905484. DOI: 10.21873/invivo.13511.


Miniature side-view dual axes confocal endomicroscope for repetitive in vivo imaging.

Shirazi A, Sahraeibelverdi T, Lee M, Li H, Yu J, Jaiswal S Biomed Opt Express. 2023; 14(8):4277-4295.

PMID: 37799693 PMC: 10549747. DOI: 10.1364/BOE.494210.


Low Power Compact 3D-Constructed AlScN Piezoelectric MEMS Mirrors for Various Scanning Strategies.

Hwang J, Wysocki L, Yarar E, Wille G, Rohr F, Albers J Micromachines (Basel). 2023; 14(9).

PMID: 37763952 PMC: 10535209. DOI: 10.3390/mi14091789.


References
1.
Lee S, Moon J, West J . Three-dimensional micropatterning of bioactive hydrogels via two-photon laser scanning photolithography for guided 3D cell migration. Biomaterials. 2008; 29(20):2962-8. PMC: 3942083. DOI: 10.1016/j.biomaterials.2008.04.004. View

2.
Brown E, Campbell R, Tsuzuki Y, Xu L, Carmeliet P, Fukumura D . In vivo measurement of gene expression, angiogenesis and physiological function in tumors using multiphoton laser scanning microscopy. Nat Med. 2001; 7(7):864-8. DOI: 10.1038/89997. View

3.
Seo Y, Hwang K, Park H, Jeong K . Electrothermal MEMS fiber scanner for optical endomicroscopy. Opt Express. 2016; 24(4):3903-9. DOI: 10.1364/OE.24.003903. View

4.
Park H, Seo Y, Hwang K, Lim J, Yoon S, Jeong K . Micromachined tethered silicon oscillator for an endomicroscopic Lissajous fiber scanner. Opt Lett. 2014; 39(23):6675-8. DOI: 10.1364/OL.39.006675. View

5.
Tuma T, Lygeros J, Kartik V, Sebastian A, Pantazi A . High-speed multiresolution scanning probe microscopy based on Lissajous scan trajectories. Nanotechnology. 2012; 23(18):185501. DOI: 10.1088/0957-4484/23/18/185501. View