» Articles » PMID: 29049964

The Bit Doesn't Fit: Evaluation of a Commercial Activity-tracker at Slower Walking Speeds

Overview
Journal Gait Posture
Specialty Orthopedics
Date 2017 Oct 20
PMID 29049964
Citations 18
Authors
Affiliations
Soon will be listed here.
Abstract

Accelerometer-based commercial activity trackers are a low-cost and convenient method for monitoring and assessing health measures such as gait. However, the accuracy of these activity trackers in slow walking conditions on a minute-by-minute basis is largely unknown. In this study, the accuracy of a hip-worn commercial activity tracker (FitBit Ultra) was examined through step counts. Accuracy was evaluated through four minute trials of treadmill walking at speeds representative of older adults (0.9, 1.1, and 1.3m/s). Minute-by-minute step count was extracted through the FitBit API and compared it to observer counted steps through video recordings. Results highlighted a significant over-reporting of steps at the highest speed, and a significant under-reporting of steps at the slowest speed, with the FitBit Ultra failing to count steps for one or more minutes at the slowest speed for 11 participants. This study highlights problems with using the FitBit Ultra by slow-walking populations, and recommends that researchers and clinicians should carefully consider the trade-off between accuracy and convenience when using commercial activity trackers with slow-walking populations.

Citing Articles

Multi-Activity Step Counting Algorithm Using Deep Learning Foot Flat Detection with an IMU Inside the Sole of a Shoe.

Lucot Q, Beurienne E, Behr M Sensors (Basel). 2024; 24(21).

PMID: 39517826 PMC: 11548453. DOI: 10.3390/s24216927.


Accuracy of wrist-worn activity trackers for measuring steps in patients after major abdominal surgery: A validation study.

Li Z, Feng W, Zhou L, Gong S Digit Health. 2024; 10:20552076241297036.

PMID: 39502479 PMC: 11536558. DOI: 10.1177/20552076241297036.


Smart Tattoo Sensors 2.0: A Ten-Year Progress Report through a Narrative Review.

Pirrera A, Giansanti D Bioengineering (Basel). 2024; 11(4).

PMID: 38671797 PMC: 11048663. DOI: 10.3390/bioengineering11040376.


Exploring the Major Barriers to Physical Activity in Persons With Multiple Sclerosis: Observational Longitudinal Study.

Sieber C, Haag C, Polhemus A, Haile S, Sylvester R, Kool J JMIR Rehabil Assist Technol. 2024; 11:e52733.

PMID: 38498024 PMC: 10985607. DOI: 10.2196/52733.


Non-equivalent, but still valid: Establishing the construct validity of a consumer fitness tracker in persons with multiple sclerosis.

Polhemus A, Sieber C, Haag C, Sylvester R, Kool J, Gonzenbach R PLOS Digit Health. 2023; 2(1):e0000171.

PMID: 36812638 PMC: 9931345. DOI: 10.1371/journal.pdig.0000171.