Imaging the Infant Chest Without Sedation: Feasibility of Using Single Axial Rotation with 16-cm Wide-Detector CT

Overview
Journal Radiology
Specialty Radiology
Date 2017 Sep 29
PMID 28956735
Citations 9
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose To compare image quality, patient preparation time, and radiation dose using a single axial rotation with 16-cm wide-detector computed tomography (CT) in imaging the infant chest without sedation with those in infants examined by using a 64-row CT and sedation. Materials and Methods Thirty-two infants (group 1) were prospectively enrolled to undergo nonenhanced chest CT without sedation using a single axial rotation on a 16-cm wide-detector CT scanner. Patients were imaged with automatic tube current modulation and tube voltages of 80 kVp for patients weighing 5 kg or less and 100 kVp for patients weighing more than 5 kg. Patient preparation time, CT dose index (CTDI), dose-length product (DLP), and image quality were compared with those in a historical control group consisting of 30 infants (group 2) who underwent conventional helical scanning with sedation performed by using a 64-row volume CT scanner. The Student t test for independent samples was used to assess continuous variables. The Mann-Whitney rank test and the κ test were used to evaluate image quality. Results There was no statistically significant difference in body weight, age, mean CT attenuation value, image noise, and subjective image quality score between the two groups. However, compared with the group scanned by using a 64-row volume CT scanner (group 2), group 1 experienced significantly reduced scan time by 83% (0.35 second vs 2.01 seconds ± 0.21 [standard deviation]), preparation time by 57% (41.25 minutes ± 103.78 vs 96.5 minutes ± 151.77), CTDI by 42% (2.03 mGy ± 0.4 vs 3.52 mGy ± 0.03), and DLP by 52% (27.07 mGy·cm ± 6.97 vs 55.84 mGy·cm ± 6.46) (P < .05 for all). Conclusion Compared with conventional 64-row helical CT with sedation, use of a single axial rotation with 16-cm wide-detector CT in imaging the infant chest without sedation can reduce radiation dose, preparation time, and total scan time, while providing comparable image quality. RSNA, 2017.

Citing Articles

Reducing Sedation for Pediatric Thoracic CT Imaging Using Volumetric Target-mode EKG Gating.

Shah S, Young C, Morrison J, Chmil M, Ruess L, Krishnamurthy R Pediatr Qual Saf. 2024; 10(1):e779.

PMID: 39734911 PMC: 11671082. DOI: 10.1097/pq9.0000000000000779.


Awake 160-Slice Computed Tomography for Upper Airway Evaluation in 17 Dogs.

Stordalen M, Bray S, Stringer F, Stonebrook C, Guilherme S, Bray J Vet Sci. 2024; 11(8).

PMID: 39195796 PMC: 11360448. DOI: 10.3390/vetsci11080342.


Comparison of pediatric lens scattered dose measurements between axial 40-mm and helical 160-mm detector width computed tomography scan modes.

Masuda T, Kiguchi M, Fujioka C, Oku T, Ishibashi T, Katsunuma Y Pediatr Radiol. 2024; 54(7):1197-1204.

PMID: 38769141 DOI: 10.1007/s00247-024-05947-z.


Impact of beam collimation of z-overscanning on dose to the lens and thyroid gland in paediatric thoracic computed tomography imaging.

Masuda T, Kiguchi M, Fujioka C, Oku T, Ishibashi T, Katsunuma Y Pediatr Radiol. 2024; 54(5):758-763.

PMID: 38308740 DOI: 10.1007/s00247-024-05862-3.


Outpatient Respiratory Management of Infants, Children, and Adolescents with Post-Prematurity Respiratory Disease: An Official American Thoracic Society Clinical Practice Guideline.

Cristea A, Ren C, Amin R, Eldredge L, Levin J, Majmudar P Am J Respir Crit Care Med. 2021; 204(12):e115-e133.

PMID: 34908518 PMC: 8865713. DOI: 10.1164/rccm.202110-2269ST.