» Articles » PMID: 28940621

Characterization of the Diffusion Coefficient of Blood

Overview
Journal Magn Reson Med
Publisher Wiley
Specialty Radiology
Date 2017 Sep 24
PMID 28940621
Citations 14
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: To characterize the diffusion coefficient of human blood for accurate results in intravoxel incoherent motion imaging.

Methods: Diffusion-weighted MRI of blood samples from 10 healthy volunteers was acquired with a single-shot echo-planar-imaging sequence at body temperature. Effects of gradient profile (monopolar or flow-compensated), diffusion time (40-100 ms), and echo time (60-200 ms) were investigated.

Results: Although measured apparent diffusion coefficients of blood were larger for flow-compensated than for monopolar gradients, no dependence of the apparent diffusion coefficient on the diffusion time was found. Large differences between individual samples were observed, with results ranging from 1.26 to 1.66 µm /ms for flow-compensated and 0.94 to 1.52 µm /ms for monopolar gradients. Statistical analysis indicates correlations of the flow-compensated apparent diffusion coefficient with hematocrit (P = 0.007) and hemoglobin (P = 0.017), but not with mean corpuscular volume (P = 0.64). Results of Monte-Carlo simulations support the experimental observations.

Conclusions: Measured blood apparent diffusion coefficient values depend on hematocrit/hemoglobin concentration and applied gradient profile due to non-Gaussian diffusion. Because in vivo measurement is delicate, an estimation based on blood count results could be an alternative. For intravoxel incoherent motion modeling, the use of a blood self-diffusion constant D  = 1.54 ± 0.12 µm /ms for flow-compensated and D  = 1.30 ± 0.18 µm /ms for monopolar encoding is suggested. Magn Reson Med 79:2752-2758, 2018. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.

Citing Articles

Influence of Magnetic Field Strength on Intravoxel Incoherent Motion Parameters in Diffusion MRI of the Calf.

Bauchle T, Stuprich C, Loh M, Nagel A, Uder M, Laun F Tomography. 2024; 10(5):773-788.

PMID: 38787019 PMC: 11126135. DOI: 10.3390/tomography10050059.


Spatial profiling of in vivo diffusion-weighted MRI parameters in the healthy human kidney.

Gilani N, Mikheev A, Brinkmann I, Kumbella M, Babb J, Basukala D MAGMA. 2024; 37(4):671-680.

PMID: 38703246 DOI: 10.1007/s10334-024-01159-6.


Impact of velocity- and acceleration-compensated encodings on signal dropout and black-blood state in diffusion-weighted magnetic resonance liver imaging at clinical TEs.

Fuhres T, Saake M, Szczepankiewicz F, Bickelhaupt S, Uder M, Laun F PLoS One. 2023; 18(10):e0291273.

PMID: 37796773 PMC: 10553293. DOI: 10.1371/journal.pone.0291273.


Investigation of Inlet Conditions in The Mixing Process of Nanoparticles and Blood in a T-Shaped Microfluidic Reactor with Small Rectangular Cavities.

Karvelas E, Doulkeridis S, Karakasidis T, Sarris I Yale J Biol Med. 2023; 96(1):43-55.

PMID: 37009188 PMC: 10052591. DOI: 10.59249/FUAH2942.


Non-Invasive Blood Flow Speed Measurement Using Optics.

Zhang A, Lo Y Sensors (Basel). 2022; 22(3).

PMID: 35161643 PMC: 8838687. DOI: 10.3390/s22030897.


References
1.
Carr R, Wickham L . Influence of vessel diameter on red cell distribution at microvascular bifurcations. Microvasc Res. 1991; 41(2):184-96. DOI: 10.1016/0026-2862(91)90020-c. View

2.
Ahn C, Lee S, Nalcioglu O, Cho Z . The effects of random directional distributed flow in nuclear magnetic resonance imaging. Med Phys. 1987; 14(1):43-8. DOI: 10.1118/1.596093. View

3.
Bruno E, Digilio G, Cabella C, de Reggi A, Baroni S, Mainero V . Water exchange across the erythrocyte plasma membrane studied by HR-MAS NMR spectroscopy. Magn Reson Med. 2006; 56(5):978-85. DOI: 10.1002/mrm.21054. View

4.
Perkkio J, Keskinen R . Hematocrit reduction in bifurcations due to plasma skimming. Bull Math Biol. 1983; 45(1):41-50. DOI: 10.1007/BF02459386. View

5.
Henkelman R, Neil J, Xiang Q . A quantitative interpretation of IVIM measurements of vascular perfusion in the rat brain. Magn Reson Med. 1994; 32(4):464-9. DOI: 10.1002/mrm.1910320407. View