» Articles » PMID: 28792374

Evaluation of an Automated Quantitative Latex Immunoturbidimetric Non-treponemal Assay for Diagnosis and Follow-up of Syphilis: a Prospective Cohort Study

Overview
Journal J Med Microbiol
Specialty Microbiology
Date 2017 Aug 10
PMID 28792374
Citations 3
Authors
Affiliations
Soon will be listed here.
Abstract

We evaluated the Sekure rapid plasma reagin (RPR-S) (Sekisui Diagnostics) automated quantitative latex immunoturbidimetric assay performed on the SK500 clinical chemistry system for clinical appropriateness. Syphilis-infected individuals and controls were recruited into a prospective cohort study conducted at a sexually transmitted infection clinic in Antwerp, Belgium. Sera collected at diagnosis (baseline) and at 3, 6, 9 and 12 months post-treatment were tested with RPR-S and Macro-Vue RPR card (RPR-C) (Becton Dickinson) assays; RPR-C was considered the reference test. IgG/IgM enzyme immunoassay and serum PCR results were consulted by discordancy at baseline. Categorical analyses were performed and correlations were assessed with (non)-linear regression. Post-treatment longitudinal serological evolution was evaluated. A total of 463 samples from 120 new syphilis cases from a variety of clinical stages and 30 syphilis-negative controls were tested. Initially, there was a weak correlation between quantitative RPR-C/S (=0.15). In 70 samples there was a strong suspicion of hook effect. Of these, 57/70 sera were retested with an extra dilution step, resulting in an average 12-fold increase in quantitative RPR-S results. After the extra dilution, the overall qualitative RPR-C/S agreement was 78.89 %, (κ-coefficient: 0.484). Of the 92 discordant samples, 9 were from the baseline visit (RPR-C titre: 1-8), which could have led to possible missed diagnoses using the RPR-S. The sensitivity and accuracy of the RPR-S test requires improvement before it can be used to diagnose syphilis and evaluate treatment efficacy in clinical practice.

Citing Articles

Role of IgM testing in the diagnosis and post-treatment follow-up of syphilis: a prospective cohort study.

Osbak K, Tsoumanis A, De Baetselier I, Van Esbroek M, Smet H, Kenyon C BMJ Open. 2020; 10(9):e035838.

PMID: 32958482 PMC: 7507855. DOI: 10.1136/bmjopen-2019-035838.


Usefulness of Automated Latex Turbidimetric Rapid Plasma Reagin Test for Diagnosis and Evaluation of Treatment Response in Syphilis in Comparison with Manual Card Test: a Prospective Cohort Study.

Tsuboi M, Nishijima T, Aoki T, Teruya K, Kikuchi Y, Gatanaga H J Clin Microbiol. 2018; 56(11).

PMID: 30135229 PMC: 6204675. DOI: 10.1128/JCM.01003-18.


Challenges of Rapid Plasma Reagin Interpretation in Syphilis Screening in Uganda: Variability in Nontreponemal Results Between Different Laboratories.

Hamill M, Mbazira K, Kiragga A, Gaydos C, Jett-Goheen M, Parkes-Ratanshi R Sex Transm Dis. 2018; 45(12):829-833.

PMID: 29944643 PMC: 6234093. DOI: 10.1097/OLQ.0000000000000883.